Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC,tolerance=0.001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8339/0.8339, allocations: 150.9 MB / 167.2 MB, free: 14.27 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0003508/0.0003508, allocations: 16.7 kB / 237.8 MB, free: 1.801 MB / 190.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.0565/0.05687, allocations: 31.34 MB / 269.2 MB, free: 6.992 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC): time 1.769/1.826, allocations: 403 MB / 0.6564 GB, free: 0.8477 MB / 0.5294 GB Notification: Performance of NFInst.instExpressions: time 0.6711/2.497, allocations: 250.4 MB / 0.9009 GB, free: 13.51 MB / 0.67 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02863/2.525, allocations: 449.8 kB / 0.9013 GB, free: 13.07 MB / 0.67 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:104:3-105:67:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:109:3-111:57:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:112:3-113:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SinkP.mo:46:3-47:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:119:3-120:52:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:121:3-122:53:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:129:3-130:55:writable] Warning: Connector Cee is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:131:3-132:53:writable] Warning: Connector Cse is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceQ.mo:62:3-63:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SinkP.mo:46:3-47:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:104:3-105:67:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:109:3-110:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:111:3-112:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceQ.mo:62:3-63:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.02248/2.548, allocations: 6.076 MB / 0.9072 GB, free: 6.984 MB / 0.67 GB Notification: Performance of NFTyping.typeBindings: time 0.05607/2.604, allocations: 18.33 MB / 0.9251 GB, free: 4.547 MB / 0.6856 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/Fluid/derDensity_derP_derh.mo:63:5-63:84:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.1054/2.71, allocations: 36.06 MB / 0.9604 GB, free: 0.5391 MB / 0.7169 GB Notification: Performance of NFFlatten.flatten: time 1.034/3.743, allocations: 110.7 MB / 1.068 GB, free: 42.68 MB / 0.7638 GB Notification: Performance of NFFlatten.resolveConnections: time 0.08831/3.832, allocations: 39.3 MB / 1.107 GB, free: 36.91 MB / 0.7638 GB Notification: Performance of NFEvalConstants.evaluate: time 0.09352/3.925, allocations: 36.57 MB / 1.143 GB, free: 16.8 MB / 0.7638 GB Notification: Performance of NFSimplifyModel.simplify: time 0.09035/4.016, allocations: 40.69 MB / 1.182 GB, free: 10.5 MB / 0.795 GB Notification: Performance of NFPackage.collectConstants: time 0.04128/4.057, allocations: 8.305 MB / 1.19 GB, free: 2.191 MB / 0.795 GB Notification: Performance of NFFlatten.collectFunctions: time 0.1118/4.169, allocations: 39.08 MB / 1.229 GB, free: 12.21 MB / 0.8419 GB Notification: Performance of NFScalarize.scalarize: time 0.05598/4.225, allocations: 24.42 MB / 1.252 GB, free: 4.266 MB / 0.8575 GB Notification: Performance of NFVerifyModel.verify: time 0.1129/4.338, allocations: 35.07 MB / 1.287 GB, free: 1.48 MB / 0.8888 GB Notification: Performance of NFConvertDAE.convert: time 1.388/5.726, allocations: 106.6 MB / 1.391 GB, free: 155.8 MB / 0.9514 GB Notification: Performance of FrontEnd - DAE generated: time 1.403e-05/5.726, allocations: 3.234 kB / 1.391 GB, free: 155.8 MB / 0.9514 GB Notification: Performance of FrontEnd: time 3.417e-06/5.726, allocations: 0 / 1.391 GB, free: 155.8 MB / 0.9514 GB Notification: Performance of Transformations before backend: time 0.005752/5.732, allocations: 1.781 kB / 1.391 GB, free: 155.8 MB / 0.9514 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 15109 * Number of variables: 15109 Notification: Performance of Generate backend data structure: time 0.356/6.088, allocations: 71.73 MB / 1.461 GB, free: 137.1 MB / 0.9514 GB Notification: Performance of prepare preOptimizeDAE: time 5.235e-05/6.088, allocations: 7.938 kB / 1.461 GB, free: 137.1 MB / 0.9514 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.04366/6.131, allocations: 6.06 MB / 1.467 GB, free: 134.2 MB / 0.9514 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.07444/6.206, allocations: 24.1 MB / 1.49 GB, free: 128.6 MB / 0.9514 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.02448/6.23, allocations: 15.58 MB / 1.505 GB, free: 116.9 MB / 0.9514 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.03578/6.266, allocations: 4.699 MB / 1.51 GB, free: 116.8 MB / 0.9514 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.2945/6.561, allocations: 96.56 MB / 1.604 GB, free: 24.96 MB / 0.9514 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.002728/6.564, allocations: 189.8 kB / 1.605 GB, free: 24.88 MB / 0.9514 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.03053/6.594, allocations: 1.965 MB / 1.606 GB, free: 22.92 MB / 0.9514 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001616/6.596, allocations: 1.705 MB / 1.608 GB, free: 21.21 MB / 0.9514 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.3066/6.902, allocations: 114.3 MB / 1.72 GB, free: 3.887 MB / 1.045 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.9974/7.9, allocations: 398.5 MB / 2.109 GB, free: 192.4 MB / 1.045 GB Notification: Performance of preOpt comSubExp (simulation): time 0.1914/8.091, allocations: 84.58 MB / 2.192 GB, free: 107.8 MB / 1.045 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.1329/8.224, allocations: 56.1 MB / 2.246 GB, free: 51.93 MB / 1.045 GB Notification: Performance of preOpt evalFunc (simulation): time 1.964/10.19, allocations: 0.7047 GB / 2.951 GB, free: 415.4 MB / 1.045 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.1756/10.36, allocations: 61.31 MB / 3.011 GB, free: 403.1 MB / 1.045 GB Notification: Performance of pre-optimization done (n=7660): time 0.0002385/10.36, allocations: 0.75 kB / 3.011 GB, free: 403.1 MB / 1.045 GB Notification: Performance of matching and sorting (n=7668): time 1.696/12.06, allocations: 397.3 MB / 3.399 GB, free: 394.7 MB / 1.045 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0004828/12.06, allocations: 1.537 MB / 3.4 GB, free: 393.4 MB / 1.045 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.03505/12.1, allocations: 20.22 MB / 3.42 GB, free: 379.4 MB / 1.045 GB Notification: Performance of collectPreVariables (initialization): time 0.02211/12.12, allocations: 0.7823 MB / 3.421 GB, free: 378.7 MB / 1.045 GB Notification: Performance of collectInitialEqns (initialization): time 0.01344/12.13, allocations: 16.39 MB / 3.437 GB, free: 363.8 MB / 1.045 GB Notification: Performance of collectInitialBindings (initialization): time 0.03922/12.17, allocations: 26.12 MB / 3.462 GB, free: 337.9 MB / 1.045 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.464/12.63, allocations: 13.14 MB / 3.475 GB, free: 468.7 MB / 1.045 GB Notification: Performance of setup shared object (initialization): time 5.962e-05/12.63, allocations: 309.1 kB / 3.476 GB, free: 468.4 MB / 1.045 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.1403/12.78, allocations: 50.66 MB / 3.525 GB, free: 467.9 MB / 1.045 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.1495/12.92, allocations: 66.2 MB / 3.59 GB, free: 433.8 MB / 1.045 GB Notification: Performance of analyzeInitialSystem (initialization): time 1.561/14.49, allocations: 335.3 MB / 3.917 GB, free: 390.9 MB / 1.045 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0006659/14.49, allocations: 118.6 kB / 3.917 GB, free: 390.9 MB / 1.045 GB Notification: Performance of matching and sorting (n=10041) (initialization): time 0.915/15.4, allocations: 170.4 MB / 4.084 GB, free: 408.7 MB / 1.045 GB Notification: Performance of prepare postOptimizeDAE: time 0.0004601/15.4, allocations: 239.9 kB / 4.084 GB, free: 408.6 MB / 1.045 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.001494/15.4, allocations: 0.5205 MB / 4.084 GB, free: 408.6 MB / 1.045 GB Notification: Performance of postOpt tearingSystem (initialization): time 6.804/22.21, allocations: 2.394 GB / 6.478 GB, free: 396.8 MB / 1.045 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.03711/22.24, allocations: 8.096 MB / 6.486 GB, free: 391 MB / 1.045 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.8853/23.13, allocations: 184.8 MB / 6.667 GB, free: 412.9 MB / 1.045 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.08247/23.21, allocations: 6.937 MB / 6.673 GB, free: 412.9 MB / 1.045 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.02681/23.24, allocations: 2.983 MB / 6.676 GB, free: 412.9 MB / 1.045 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP4.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP3.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurMP3.TwoPhaseFlowPipe.Q[1] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1905 * Number of states: 0 () * Number of discrete variables: 400 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,VolumeAlimMPHP.Cs1.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK.C2.diff_on_2,vanne_extraction.C2.diff_on_1,perteChargeK2.C2.diff_on_1,SourceFumees.C.ftype,DoubleDebitMP.Cs.ftype,MelangeurPreTMP.Cs.ftype,MelangeurPreTMP.Ce3.ftype,MelangeurPreTMP.Ce2.ftype,MelangeurPreTMP.fluids[1],VolumePreTHP.Cs3.ftype,VolumePreTHP.Cs2.ftype,VolumePreTHP.Cs1.ftype,DoubleDebitHP.Cs.ftype,VolumePreTHP.fluids[1],VolumeAlimMPHP.Cs1.ftype,VolumeAlimMPHP.Cs2.ftype,VolumeECO_HP2_3.Cs.ftype,VolumeECO_HP2_3.Ce3.ftype,VolumeECO_HP2_3.Ce2.ftype,VolumeECO_HP1_2.Cs.ftype,VolumeECO_HP2_3.fluids[1],VolumeECO_HP1_2.Ce3.ftype,VolumeECO_HP1_2.Ce2.ftype,VolumeECO_HP1_2.fluids[1],regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,MelangeurHPMP.Cs2.ftype,MelangeurPostTMP1.Cs.ftype,Condenseur.Cl.ftype,BallonBP.Cs.ftype,VolumeCond1.Cs.ftype,BallonBP.Cv.ftype,BallonMP.Cv.ftype,BallonHP.Cv.ftype,DoubleDebitBP.Cs.ftype,DoubleDebitBP.fluids[1],MoitieDebitBP.Cs.ftype,MoitieDebitBP.fluids[1],VolumeAlimMPHP.Ce2.ftype,VolumeAlimMPHP.fluids[1],VolumeCond1.Ce2.ftype,VolumeCond1.Ce1.ftype,VolumeCond1.fluids[1],SourceCaloporteur.C.ftype,MoitieDebitHP.Cs.ftype,MoitieDebitHP.fluids[1],DoubleDebitMP.fluids[1],DoubleDebitHP.fluids[1],MelangeurPostTMP1.Ce3.ftype,MelangeurPostTMP1.fluids[1],VolumeEvapBP.Cs.ftype,VolumeEvapBP.Ce3.ftype,VolumeEvapBP.Ce2.ftype,BallonBP.Cd.ftype,VolumeEvapBP.fluids[1],BallonBP.Ce3.ftype,BallonBP.Ce2.ftype,BallonBP.fluids[1],MelangeurHPMP.Cs1.ftype,MelangeurHPMP.fluids[1],VolumeEvapMP.Cs.ftype,VolumeEvapMP.Ce3.ftype,VolumeEvapMP.Ce2.ftype,BallonMP.Cd.ftype,VolumeEvapMP.fluids[1],BallonMP.Cs.ftype,BallonMP.Ce3.ftype,BallonMP.Ce2.ftype,BallonMP.fluids[1],VolumeEvapHP.Cs.ftype,VolumeEvapHP.Ce3.ftype,VolumeEvapHP.Ce2.ftype,BallonHP.Cd.ftype,VolumeEvapHP.fluids[1],BallonHP.Cs.ftype,BallonHP.Ce3.ftype,BallonHP.Ce2.ftype,BallonHP.fluids[1],vanne_alimentationHP.fluid,vanne_vapeurHP.fluid,GainChargeHP.fluid,EvaporateurHP.ExchangerFlueGasesMetal.fluid,EvaporateurHP.TwoPhaseFlowPipe.fluid,EconomiseurHP4.ExchangerFlueGasesMetal.fluid,EconomiseurHP4.TwoPhaseFlowPipe.fluid,SurchauffeurHP1.ExchangerFlueGasesMetal.fluid,SurchauffeurHP1.TwoPhaseFlowPipe.fluid,EconomiseurHP3.ExchangerFlueGasesMetal.fluid,EconomiseurHP3.TwoPhaseFlowPipe.fluid,EconomiseurHP2.ExchangerFlueGasesMetal.fluid,EconomiseurHP2.TwoPhaseFlowPipe.fluid,EconomiseurHP1.ExchangerFlueGasesMetal.fluid,EconomiseurHP1.TwoPhaseFlowPipe.fluid,SurchauffeurHP2.ExchangerFlueGasesMetal.fluid,SurchauffeurHP2.TwoPhaseFlowPipe.fluid,SurchauffeurHP3.ExchangerFlueGasesMetal.fluid,SurchauffeurHP3.TwoPhaseFlowPipe.fluid,vanne_alimentationMP.fluid,vanne_vapeurMP.fluid,EvaporateurMP.ExchangerFlueGasesMetal.fluid,EvaporateurMP.TwoPhaseFlowPipe.fluid,GainChargeMP.fluid,EconomiseurMP.ExchangerFlueGasesMetal.fluid,EconomiseurMP.TwoPhaseFlowPipe.fluid,SurchauffeurMP1.ExchangerFlueGasesMetal.fluid,SurchauffeurMP1.TwoPhaseFlowPipe.fluid,SurchauffeurMP2.ExchangerFlueGasesMetal.fluid,SurchauffeurMP2.TwoPhaseFlowPipe.fluid,SurchauffeurMP3.ExchangerFlueGasesMetal.fluid,SurchauffeurMP3.TwoPhaseFlowPipe.fluid,vanne_vapeurBP.fluid,vanne_alimentationBP.fluid,GainChargeBP.fluid,EvaporateurBP.ExchangerFlueGasesMetal.fluid,EvaporateurBP.TwoPhaseFlowPipe.fluid,Vanne_alimentationMPHP.fluid,SurchauffeurBP.ExchangerFlueGasesMetal.fluid,SurchauffeurBP.TwoPhaseFlowPipe.fluid,PuitsFumees.fluid,EconomiseurBP.ExchangerFlueGasesMetal.fluid,EconomiseurBP.TwoPhaseFlowPipe.fluid,TurbineHP.fluid,TurbineMP.fluid,TurbineBP.fluid,Condenseur.fluid_p,PuitsCaloporteur.fluid,perteChargeK1.fluid,perteChargeKCond1.fluid,PompeAlimMP.fluid,PompeAlimHP.fluid,PerteChargeZero2.fluid,perteChargeK3.fluid,perteChargeK8.fluid,perteChargeK.fluid,PompeAlimBP.fluid,perteChargeK2.fluid,vanne_extraction.fluid,lumpedStraightPipeK2.fluid,vanne_entree_TurbineHP.fluid,Vanne_alimentationMPHP1.fluid,Vanne_alimentationMPHP2.fluid,vanne_entree_TurbineMP.fluid,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,$whenCondition1,SourceFumees.fluid1,MelangeurPreTMP.fluid1,VolumePreTHP.fluid1,VolumeECO_HP2_3.fluid1,VolumeECO_HP1_2.fluid1,DoubleDebitBP.fluid1,MoitieDebitBP.fluid1,VolumeAlimMPHP.fluid1,VolumeCond1.fluid1,SourceCaloporteur.fluid1,MoitieDebitHP.fluid1,DoubleDebitMP.fluid1,DoubleDebitHP.fluid1,MelangeurPostTMP1.fluid1,VolumeEvapBP.fluid1,MelangeurHPMP.fluid1,VolumeEvapMP.fluid1,VolumeEvapHP.fluid1,MelangeurPreTMP.Ce1.diff_on_2,DoubleDebitMP.Cs.diff_on_2,DoubleDebitMP.Cs.diff_on_1,vanne_entree_TurbineMP.C2.diff_on_1,MelangeurPreTMP.Cs.diff_on_1,TurbineMP.Cs.diff_on_1,MelangeurPreTMP.Ce3.diff_on_2,MelangeurPreTMP.Ce2.diff_on_2,MelangeurPreTMP.Ce3.diff_on_1,MelangeurPreTMP.Ce2.diff_on_1,VolumePreTHP.Cs3.diff_on_1,TurbineHP.Cs.diff_on_1,VolumePreTHP.Cs2.diff_on_1,VolumePreTHP.Cs1.diff_on_1,VolumePreTHP.Ce.diff_on_2,DoubleDebitHP.Cs.diff_on_2,VolumePreTHP.Cs2.diff_on_2,VolumePreTHP.Cs1.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C1.diff_on_2,PompeAlimMP.C2.diff_on_2,perteChargeK8.C2.diff_on_2,VolumeAlimMPHP.Cs1.diff_on_1,perteChargeK8.C2.diff_on_1,PompeAlimMP.C2.diff_on_1,EconomiseurHP1.TwoPhaseFlowPipe.C1.diff_on_2,Vanne_alimentationMPHP1.C1.diff_on_2,perteChargeK3.C2.diff_on_2,VolumeAlimMPHP.Cs2.diff_on_1,perteChargeK3.C2.diff_on_1,Vanne_alimentationMPHP1.C1.diff_on_1,VolumeECO_HP2_3.Cs.diff_on_1,VolumeECO_HP2_3.Ce3.diff_on_2,VolumeECO_HP2_3.Ce2.diff_on_2,VolumeECO_HP2_3.Ce1.diff_on_2,VolumeECO_HP2_3.Ce3.diff_on_1,VolumeECO_HP2_3.Ce2.diff_on_1,VolumeECO_HP1_2.Cs.diff_on_1,VolumeECO_HP1_2.Ce3.diff_on_2,VolumeECO_HP1_2.Ce2.diff_on_2,VolumeECO_HP1_2.Ce1.diff_on_2,VolumeECO_HP1_2.Ce3.diff_on_1,VolumeECO_HP1_2.Ce2.diff_on_1,DoubleDebitHP.Cs.diff_on_1,vanne_entree_TurbineHP.C2.diff_on_1,SurchauffeurMP2.TwoPhaseFlowPipe.C1.diff_on_2,lumpedStraightPipeK2.C1.diff_on_2,MelangeurHPMP.Cs2.diff_on_1,SurchauffeurMP2.Cws1.diff_on_1,Condenseur.Cv.diff_on_2,TurbineBP.Cs.diff_on_2,MelangeurPostTMP1.Cs.diff_on_2,MelangeurPostTMP1.Cs.diff_on_1,TurbineBP.Cs.diff_on_1,CapteurDebitVapCondenseur.C2.diff_on_1,MoitieDebitBP.Ce.diff_on_2,vanne_extraction.C2.diff_on_2,PompeAlimBP.C2.diff_on_2,Condenseur.Cl.diff_on_1,perteChargeK.C2.diff_on_1,PompeAlimBP.C2.diff_on_1,VolumeAlimMPHP.Ce1.diff_on_2,CapteurDebitEauBPsortie.C1.diff_on_2,BallonBP.Cs.diff_on_1,Vanne_alimentationMPHP.C2.diff_on_1,BallonBP.Ce1.diff_on_2,CapteurDebitEauBP.C1.diff_on_2,EconomiseurBP.TwoPhaseFlowPipe.C2.diff_on_1,BallonBP.Ce1.diff_on_1,SurchauffeurBP.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurBP.C1.diff_on_2,BallonBP.Cv.diff_on_1,CapteurDebitVapBP.C2.diff_on_1,SurchauffeurMP1.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurMP.C1.diff_on_2,BallonMP.Cv.diff_on_1,CapteurDebitVapMP.C2.diff_on_1,BallonMP.Ce1.diff_on_2,CapteurDebitEauMP.C1.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C2.diff_on_1,BallonMP.Ce1.diff_on_1,BallonHP.Ce1.diff_on_2,CapteurDebitEauHP.C1.diff_on_2,EconomiseurHP4.TwoPhaseFlowPipe.C2.diff_on_1,BallonHP.Ce1.diff_on_1,SurchauffeurHP1.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurHP.C1.diff_on_2,BallonHP.Cv.diff_on_1,CapteurDebitVapHP.C2.diff_on_1,MelangeurPostTMP1.Ce2.diff_on_2,DoubleDebitBP.Cs.diff_on_2,DoubleDebitBP.Cs.diff_on_1,MelangeurPostTMP1.Ce2.diff_on_1,DoubleDebitBP.Ce.diff_on_2,MoitieDebitBP.Cs.diff_on_1,VolumeAlimMPHP.Ce2.diff_on_2,VolumeAlimMPHP.Ce2.diff_on_1,EconomiseurBP.TwoPhaseFlowPipe.C1.diff_on_2,VolumeCond1.Cs.diff_on_2,VolumeCond1.Cs.diff_on_1,EconomiseurBP.Cws1.diff_on_1,VolumeCond1.Ce3.diff_on_2,VolumeCond1.Ce2.diff_on_2,VolumeCond1.Ce1.diff_on_2,VolumeCond1.Ce2.diff_on_1,VolumeCond1.Ce1.diff_on_1,MoitieDebitHP.Cs.diff_on_1,MoitieDebitHP.Ce.diff_on_2,VolumePreTHP.Cs3.diff_on_2,DoubleDebitMP.Ce.diff_on_2,DoubleDebitHP.Ce.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_2,MelangeurPostTMP1.Ce1.diff_on_2,MelangeurPreTMP.Cs.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_1,EconomiseurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurBP.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurBP.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurBP.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurBP.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurBP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurBP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurBP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapBP.Cs.diff_on_1,VolumeEvapBP.Ce3.diff_on_2,VolumeEvapBP.Ce2.diff_on_2,VolumeEvapBP.Ce1.diff_on_2,BallonBP.Cd.diff_on_2,VolumeEvapBP.Ce3.diff_on_1,VolumeEvapBP.Ce2.diff_on_1,BallonBP.Cd.diff_on_1,VolumeEvapBP.Ce1.diff_on_1,BallonBP.Cm.diff_on_2,BallonBP.Ce3.diff_on_2,BallonBP.Ce2.diff_on_2,BallonBP.Ce3.diff_on_1,BallonBP.Ce2.diff_on_1,SurchauffeurMP3.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurMP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurMP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.diff_on_1,MelangeurHPMP.Cs1.diff_on_1,MelangeurHPMP.Ce2.diff_on_2,MelangeurHPMP.Ce1.diff_on_2,MelangeurHPMP.Cs1.diff_on_2,SurchauffeurMP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurMP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapMP.Cs.diff_on_1,VolumeEvapMP.Ce3.diff_on_2,VolumeEvapMP.Ce2.diff_on_2,VolumeEvapMP.Ce1.diff_on_2,GainChargeMP.C1.diff_on_2,VolumeEvapMP.Ce3.diff_on_1,VolumeEvapMP.Ce2.diff_on_1,BallonMP.Cd.diff_on_1,VolumeEvapMP.Ce1.diff_on_1,EvaporateurMP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurMP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurMP.ExchangerFlueGasesMetal.C2.diff_on_1,BallonMP.Cs.diff_on_1,BallonMP.Cm.diff_on_2,BallonMP.Ce3.diff_on_2,BallonMP.Ce2.diff_on_2,BallonMP.Cs.diff_on_2,BallonMP.Ce3.diff_on_1,BallonMP.Ce2.diff_on_1,SurchauffeurHP3.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP2.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP1.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP2.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP2.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP3.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP3.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP4.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurHP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurHP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurHP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurHP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapHP.Cs.diff_on_1,VolumeEvapHP.Ce3.diff_on_2,VolumeEvapHP.Ce2.diff_on_2,VolumeEvapHP.Ce1.diff_on_2,GainChargeHP.C1.diff_on_2,VolumeEvapHP.Ce3.diff_on_1,VolumeEvapHP.Ce2.diff_on_1,BallonHP.Cd.diff_on_1,VolumeEvapHP.Ce1.diff_on_1,BallonHP.Cs.diff_on_1,BallonHP.Cm.diff_on_2,BallonHP.Ce3.diff_on_2,BallonHP.Ce2.diff_on_2,BallonHP.Cs.diff_on_2,BallonHP.Ce3.diff_on_1,BallonHP.Ce2.diff_on_1) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (3642): * Single equations (assignments): 3589 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 34 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 5 * Torn equation systems: 12 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 5 systems {1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(4,1,62.5%)} * Non-linear torn systems (#iteration vars, #inner vars): 11 systems {(1,1), (1,5), (2,11), (1,15), (1,1), (1,15), (305,2988), (1,1), (1,1), (1,1), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.07514/23.31, allocations: 12.76 MB / 6.689 GB, free: 412.7 MB / 1.045 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.03131/23.35, allocations: 3.951 MB / 6.693 GB, free: 412.7 MB / 1.045 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.5572/23.9, allocations: 164.6 MB / 6.853 GB, free: 362 MB / 1.045 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.8741/24.78, allocations: 144.6 MB / 6.994 GB, free: 425.6 MB / 1.045 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0003508/24.78, allocations: 23.34 kB / 6.994 GB, free: 425.6 MB / 1.045 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.002046/24.78, allocations: 302.4 kB / 6.995 GB, free: 425.6 MB / 1.045 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 1.214/25.99, allocations: 269.4 MB / 7.258 GB, free: 405.8 MB / 1.045 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.001546/26, allocations: 142.9 kB / 7.258 GB, free: 405.8 MB / 1.045 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.07212/26.07, allocations: 12.99 MB / 7.271 GB, free: 405.8 MB / 1.045 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.1268/26.19, allocations: 40.95 MB / 7.311 GB, free: 404.1 MB / 1.045 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.02812/26.22, allocations: 2.067 MB / 7.313 GB, free: 404.1 MB / 1.045 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.8071/27.03, allocations: 296.8 MB / 7.603 GB, free: 367.1 MB / 1.045 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 2.144e-05/27.03, allocations: 34.38 kB / 7.603 GB, free: 367.1 MB / 1.045 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 1.045/28.07, allocations: 223.4 MB / 7.821 GB, free: 386.5 MB / 1.045 GB Notification: Performance of postOpt removeConstants (simulation): time 0.05158/28.13, allocations: 13.66 MB / 7.834 GB, free: 386.4 MB / 1.045 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.03065/28.16, allocations: 1.246 MB / 7.835 GB, free: 386.4 MB / 1.045 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.08144/28.24, allocations: 6.347 MB / 7.841 GB, free: 386.4 MB / 1.045 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.03181/28.27, allocations: 4.586 MB / 7.846 GB, free: 386.4 MB / 1.045 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.02448/28.3, allocations: 2.239 MB / 7.848 GB, free: 386.4 MB / 1.045 GB Notification: Performance of sorting global known variables: time 0.03104/28.33, allocations: 12.49 MB / 7.86 GB, free: 385.7 MB / 1.045 GB Notification: Performance of sort global known variables: time 3.81e-07/28.33, allocations: 3.062 kB / 7.86 GB, free: 385.7 MB / 1.045 GB Notification: Performance of remove unused functions: time 0.104/28.43, allocations: 19 MB / 7.879 GB, free: 385.7 MB / 1.045 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 105 * Number of states: 249 (BallonHP.P,BallonHP.hl,BallonHP.hv,BallonHP.Tp,BallonHP.Vv,VolumeEvapHP.h,EvaporateurHP.ExchangerWall.Tp[1],EvaporateurHP.ExchangerWall.Tp[2],EvaporateurHP.ExchangerWall.Tp[3],EvaporateurHP.TwoPhaseFlowPipe.P[2],EvaporateurHP.TwoPhaseFlowPipe.P[3],EvaporateurHP.TwoPhaseFlowPipe.P[4],EvaporateurHP.TwoPhaseFlowPipe.Q[1],EvaporateurHP.TwoPhaseFlowPipe.Q[2],EvaporateurHP.TwoPhaseFlowPipe.Q[3],EvaporateurHP.TwoPhaseFlowPipe.Q[4],EvaporateurHP.TwoPhaseFlowPipe.h[2],EvaporateurHP.TwoPhaseFlowPipe.h[3],EvaporateurHP.TwoPhaseFlowPipe.h[4],EconomiseurHP4.ExchangerWall.Tp[1],EconomiseurHP4.ExchangerWall.Tp[2],EconomiseurHP4.ExchangerWall.Tp[3],EconomiseurHP4.TwoPhaseFlowPipe.P[2],EconomiseurHP4.TwoPhaseFlowPipe.P[3],EconomiseurHP4.TwoPhaseFlowPipe.P[4],EconomiseurHP4.TwoPhaseFlowPipe.Q[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[3],EconomiseurHP4.TwoPhaseFlowPipe.Q[4],EconomiseurHP4.TwoPhaseFlowPipe.h[2],EconomiseurHP4.TwoPhaseFlowPipe.h[3],EconomiseurHP4.TwoPhaseFlowPipe.h[4],SurchauffeurHP1.ExchangerWall.Tp[1],SurchauffeurHP1.ExchangerWall.Tp[2],SurchauffeurHP1.ExchangerWall.Tp[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[2],SurchauffeurHP1.TwoPhaseFlowPipe.P[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[4],SurchauffeurHP1.TwoPhaseFlowPipe.Q[1],SurchauffeurHP1.TwoPhaseFlowPipe.Q[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[2],SurchauffeurHP1.TwoPhaseFlowPipe.h[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[4],EconomiseurHP3.ExchangerWall.Tp[1],EconomiseurHP3.ExchangerWall.Tp[2],EconomiseurHP3.ExchangerWall.Tp[3],EconomiseurHP3.TwoPhaseFlowPipe.P[2],EconomiseurHP3.TwoPhaseFlowPipe.P[3],EconomiseurHP3.TwoPhaseFlowPipe.P[4],EconomiseurHP3.TwoPhaseFlowPipe.Q[1],EconomiseurHP3.TwoPhaseFlowPipe.Q[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[3],EconomiseurHP3.TwoPhaseFlowPipe.Q[4],EconomiseurHP3.TwoPhaseFlowPipe.h[2],EconomiseurHP3.TwoPhaseFlowPipe.h[3],EconomiseurHP3.TwoPhaseFlowPipe.h[4],EconomiseurHP2.ExchangerWall.Tp[1],EconomiseurHP2.ExchangerWall.Tp[2],EconomiseurHP2.ExchangerWall.Tp[3],EconomiseurHP2.TwoPhaseFlowPipe.P[2],EconomiseurHP2.TwoPhaseFlowPipe.P[3],EconomiseurHP2.TwoPhaseFlowPipe.P[4],EconomiseurHP2.TwoPhaseFlowPipe.Q[1],EconomiseurHP2.TwoPhaseFlowPipe.Q[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[3],EconomiseurHP2.TwoPhaseFlowPipe.Q[4],EconomiseurHP2.TwoPhaseFlowPipe.h[2],EconomiseurHP2.TwoPhaseFlowPipe.h[3],EconomiseurHP2.TwoPhaseFlowPipe.h[4],EconomiseurHP1.ExchangerWall.Tp[1],EconomiseurHP1.ExchangerWall.Tp[2],EconomiseurHP1.ExchangerWall.Tp[3],EconomiseurHP1.TwoPhaseFlowPipe.P[2],EconomiseurHP1.TwoPhaseFlowPipe.P[3],EconomiseurHP1.TwoPhaseFlowPipe.P[4],EconomiseurHP1.TwoPhaseFlowPipe.Q[1],EconomiseurHP1.TwoPhaseFlowPipe.Q[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[3],EconomiseurHP1.TwoPhaseFlowPipe.Q[4],EconomiseurHP1.TwoPhaseFlowPipe.h[2],EconomiseurHP1.TwoPhaseFlowPipe.h[3],EconomiseurHP1.TwoPhaseFlowPipe.h[4],SurchauffeurHP2.ExchangerWall.Tp[1],SurchauffeurHP2.ExchangerWall.Tp[2],SurchauffeurHP2.ExchangerWall.Tp[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[2],SurchauffeurHP2.TwoPhaseFlowPipe.P[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[4],SurchauffeurHP2.TwoPhaseFlowPipe.Q[1],SurchauffeurHP2.TwoPhaseFlowPipe.Q[2],SurchauffeurHP2.TwoPhaseFlowPipe.Q[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[2],SurchauffeurHP2.TwoPhaseFlowPipe.h[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[4],SurchauffeurHP3.ExchangerWall.Tp[1],SurchauffeurHP3.ExchangerWall.Tp[2],SurchauffeurHP3.ExchangerWall.Tp[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[2],SurchauffeurHP3.TwoPhaseFlowPipe.P[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[4],SurchauffeurHP3.TwoPhaseFlowPipe.Q[1],SurchauffeurHP3.TwoPhaseFlowPipe.Q[2],SurchauffeurHP3.TwoPhaseFlowPipe.Q[3],SurchauffeurHP3.TwoPhaseFlowPipe.Q[4],SurchauffeurHP3.TwoPhaseFlowPipe.h[2],SurchauffeurHP3.TwoPhaseFlowPipe.h[3],SurchauffeurHP3.TwoPhaseFlowPipe.h[4],BallonMP.P,BallonMP.hl,BallonMP.hv,BallonMP.Tp,BallonMP.Vv,EvaporateurMP.ExchangerWall.Tp[1],EvaporateurMP.ExchangerWall.Tp[2],EvaporateurMP.ExchangerWall.Tp[3],EvaporateurMP.TwoPhaseFlowPipe.P[2],EvaporateurMP.TwoPhaseFlowPipe.P[3],EvaporateurMP.TwoPhaseFlowPipe.P[4],EvaporateurMP.TwoPhaseFlowPipe.Q[1],EvaporateurMP.TwoPhaseFlowPipe.Q[2],EvaporateurMP.TwoPhaseFlowPipe.Q[3],EvaporateurMP.TwoPhaseFlowPipe.Q[4],EvaporateurMP.TwoPhaseFlowPipe.h[2],EvaporateurMP.TwoPhaseFlowPipe.h[3],EvaporateurMP.TwoPhaseFlowPipe.h[4],VolumeEvapMP.h,EconomiseurMP.ExchangerWall.Tp[1],EconomiseurMP.ExchangerWall.Tp[2],EconomiseurMP.ExchangerWall.Tp[3],EconomiseurMP.TwoPhaseFlowPipe.P[2],EconomiseurMP.TwoPhaseFlowPipe.P[3],EconomiseurMP.TwoPhaseFlowPipe.P[4],EconomiseurMP.TwoPhaseFlowPipe.Q[1],EconomiseurMP.TwoPhaseFlowPipe.Q[2],EconomiseurMP.TwoPhaseFlowPipe.Q[3],EconomiseurMP.TwoPhaseFlowPipe.Q[4],EconomiseurMP.TwoPhaseFlowPipe.h[2],EconomiseurMP.TwoPhaseFlowPipe.h[3],EconomiseurMP.TwoPhaseFlowPipe.h[4],SurchauffeurMP1.ExchangerWall.Tp[1],SurchauffeurMP1.ExchangerWall.Tp[2],SurchauffeurMP1.ExchangerWall.Tp[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[2],SurchauffeurMP1.TwoPhaseFlowPipe.P[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[4],SurchauffeurMP1.TwoPhaseFlowPipe.Q[1],SurchauffeurMP1.TwoPhaseFlowPipe.Q[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[3],SurchauffeurMP1.TwoPhaseFlowPipe.Q[4],SurchauffeurMP1.TwoPhaseFlowPipe.h[2],SurchauffeurMP1.TwoPhaseFlowPipe.h[3],SurchauffeurMP1.TwoPhaseFlowPipe.h[4],MelangeurHPMP.h,SurchauffeurMP2.ExchangerWall.Tp[1],SurchauffeurMP2.ExchangerWall.Tp[2],SurchauffeurMP2.ExchangerWall.Tp[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[2],SurchauffeurMP2.TwoPhaseFlowPipe.P[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[4],SurchauffeurMP2.TwoPhaseFlowPipe.Q[1],SurchauffeurMP2.TwoPhaseFlowPipe.Q[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[2],SurchauffeurMP2.TwoPhaseFlowPipe.h[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[4],SurchauffeurMP3.ExchangerWall.Tp[1],SurchauffeurMP3.ExchangerWall.Tp[2],SurchauffeurMP3.ExchangerWall.Tp[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[2],SurchauffeurMP3.TwoPhaseFlowPipe.P[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[4],SurchauffeurMP3.TwoPhaseFlowPipe.Q[1],SurchauffeurMP3.TwoPhaseFlowPipe.Q[2],SurchauffeurMP3.TwoPhaseFlowPipe.Q[3],SurchauffeurMP3.TwoPhaseFlowPipe.Q[4],SurchauffeurMP3.TwoPhaseFlowPipe.h[2],SurchauffeurMP3.TwoPhaseFlowPipe.h[3],SurchauffeurMP3.TwoPhaseFlowPipe.h[4],BallonBP.P,BallonBP.hl,BallonBP.hv,BallonBP.Tp,BallonBP.Vv,VolumeEvapBP.h,EvaporateurBP.ExchangerWall.Tp[1],EvaporateurBP.ExchangerWall.Tp[2],EvaporateurBP.ExchangerWall.Tp[3],EvaporateurBP.TwoPhaseFlowPipe.P[2],EvaporateurBP.TwoPhaseFlowPipe.P[3],EvaporateurBP.TwoPhaseFlowPipe.P[4],EvaporateurBP.TwoPhaseFlowPipe.Q[1],EvaporateurBP.TwoPhaseFlowPipe.Q[2],EvaporateurBP.TwoPhaseFlowPipe.Q[3],EvaporateurBP.TwoPhaseFlowPipe.Q[4],EvaporateurBP.TwoPhaseFlowPipe.h[2],EvaporateurBP.TwoPhaseFlowPipe.h[3],EvaporateurBP.TwoPhaseFlowPipe.h[4],SurchauffeurBP.ExchangerWall.Tp[1],SurchauffeurBP.ExchangerWall.Tp[2],SurchauffeurBP.ExchangerWall.Tp[3],SurchauffeurBP.TwoPhaseFlowPipe.P[2],SurchauffeurBP.TwoPhaseFlowPipe.P[3],SurchauffeurBP.TwoPhaseFlowPipe.P[4],SurchauffeurBP.TwoPhaseFlowPipe.Q[1],SurchauffeurBP.TwoPhaseFlowPipe.Q[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[3],SurchauffeurBP.TwoPhaseFlowPipe.Q[4],SurchauffeurBP.TwoPhaseFlowPipe.h[2],SurchauffeurBP.TwoPhaseFlowPipe.h[3],SurchauffeurBP.TwoPhaseFlowPipe.h[4],EconomiseurBP.ExchangerWall.Tp[1],EconomiseurBP.ExchangerWall.Tp[2],EconomiseurBP.ExchangerWall.Tp[3],EconomiseurBP.TwoPhaseFlowPipe.P[2],EconomiseurBP.TwoPhaseFlowPipe.P[3],EconomiseurBP.TwoPhaseFlowPipe.P[4],EconomiseurBP.TwoPhaseFlowPipe.Q[1],EconomiseurBP.TwoPhaseFlowPipe.Q[2],EconomiseurBP.TwoPhaseFlowPipe.Q[3],EconomiseurBP.TwoPhaseFlowPipe.Q[4],EconomiseurBP.TwoPhaseFlowPipe.h[2],EconomiseurBP.TwoPhaseFlowPipe.h[3],EconomiseurBP.TwoPhaseFlowPipe.h[4],MelangeurPostTMP1.h,Condenseur.P,Condenseur.hl,Condenseur.hv,Condenseur.Vv,VolumeCond1.h,VolumeAlimMPHP.h,regulation_Niveau_HP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_3.x,VolumeECO_HP1_2.P,VolumeECO_HP1_2.h,VolumeECO_HP2_3.P,VolumeECO_HP2_3.h,VolumePreTHP.P,VolumePreTHP.h,MelangeurPreTMP.P,MelangeurPreTMP.h) * Number of discrete variables: 17 ($whenCondition1,regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal,perteChargeK2.C2.diff_on_1,vanne_extraction.C2.diff_on_1,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK.C2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs1.diff_on_2) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (5210): * Single equations (assignments): 4801 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 256 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 4 * Torn equation systems: 142 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 4 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 55 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,2,100.0%), (1,2,100.0%), (1,2,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 87 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,5), (1,3), (2,8), (1,5), (1,3), (2,8), (1,5), (1,5), (1,3), (1,3), (48,433), (1,4), (1,4), (1,4), (1,5), (1,3), (5,16), (1,5), (1,5), (1,2), (1,2), (4,18), (1,3), (3,9)} Notification: Performance of Backend phase and start with SimCode phase: time 0.03843/28.47, allocations: 5.795 MB / 7.885 GB, free: 385.6 MB / 1.045 GB Notification: Performance of simCode: created initialization part: time 0.373/28.84, allocations: 171 MB / 8.051 GB, free: 306.1 MB / 1.045 GB Notification: Performance of simCode: created event and clocks part: time 3.137e-05/28.84, allocations: 8 kB / 8.051 GB, free: 306.1 MB / 1.045 GB Notification: Performance of simCode: created simulation system equations: time 0.638/29.48, allocations: 90.64 MB / 8.14 GB, free: 383.2 MB / 1.045 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.1542/29.63, allocations: 15.79 MB / 8.155 GB, free: 382.1 MB / 1.045 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.5638/30.2, allocations: 183.3 MB / 8.334 GB, free: 333.3 MB / 1.045 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.07391/30.27, allocations: 29.14 MB / 8.363 GB, free: 304.6 MB / 1.045 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.0457/30.32, allocations: 4.184 MB / 8.367 GB, free: 300.4 MB / 1.045 GB Notification: Performance of SimCode: time 1.633e-06/30.32, allocations: 0 / 8.367 GB, free: 300.4 MB / 1.045 GB Notification: Performance of Templates: time 46.49/76.8, allocations: 18.25 GB / 26.62 GB, free: 281 MB / 1.045 GB make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/include/omc/sundials" "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.o OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.cpp In file included from OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.cpp:25: In file included from ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgLoopMain.cpp:186: ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:93:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp3113.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:94:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp3113.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:95:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp3113.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:96:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp3113.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:97:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp3113.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:98:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_pt_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_pt_ = get<0>(tmp3113.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:99:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cv_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cv_ = get<0>(tmp3113.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:100:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_P_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_P_ = get<1>(tmp3113.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:101:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_T_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_T_ = get<1>(tmp3113.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:102:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_rho_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_rho_ = get<1>(tmp3113.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:103:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_h_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_h_ = get<1>(tmp3113.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:104:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_cp_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_cp_ = get<1>(tmp3113.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:105:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_pt_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_pt_ = get<1>(tmp3113.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:106:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_cv_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_vsat2_P_cv_ = get<1>(tmp3113.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:147:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp3120.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:148:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp3120.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:149:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp3120.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:150:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp3120.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACAlgloop12317.cpp:151:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp3120.data).cp_; ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. make: *** [: OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTACCalcHelperMain.o] Error 1