Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant") translateModel(ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.7611/0.7611, allocations: 150.9 MB / 167.2 MB, free: 14.51 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0003132/0.0003132, allocations: 18.05 kB / 237.8 MB, free: 1.73 MB / 190.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.05179/0.05211, allocations: 31.35 MB / 269.1 MB, free: 7.023 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant): time 1.552/1.604, allocations: 377 MB / 0.631 GB, free: 10.5 MB / 0.5137 GB Notification: Performance of NFInst.instExpressions: time 0.5162/2.12, allocations: 224.3 MB / 0.85 GB, free: 15.32 MB / 0.6231 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01372/2.134, allocations: 168.5 kB / 0.8502 GB, free: 15.31 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceQ.mo:24:3-25:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:89:3-90:45:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:91:3-92:46:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:99:3-100:48:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:101:3-102:43:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:69:3-71:37:writable] Warning: Connector Ec is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:72:3-74:42:writable] Warning: Connector Ef is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:75:3-77:37:writable] Warning: Connector Sf is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:78:3-80:36:writable] Warning: Connector Sc is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:28:3-30:67:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:31:3-33:68:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:34:3-36:67:writable] Warning: Connector Ce4 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:37:3-39:74:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:40:3-42:73:writable] Warning: Connector Cs4 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:43:3-45:72:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:46:3-48:73:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:49:3-51:74:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:28:3-30:67:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:31:3-33:68:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:34:3-36:67:writable] Warning: Connector Ce4 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:37:3-39:74:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:40:3-42:73:writable] Warning: Connector Cs4 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:43:3-45:72:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:46:3-48:73:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:49:3-51:74:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:69:3-71:37:writable] Warning: Connector Ec is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:72:3-74:42:writable] Warning: Connector Ef is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:75:3-77:37:writable] Warning: Connector Sf is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:78:3-80:36:writable] Warning: Connector Sc is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorT.mo:28:3-30:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorT.mo:31:3-33:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GenericCombustion1D.mo:116:3-118:24:writable] Warning: Connector Cfuel is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GenericCombustion1D.mo:119:3-121:16:writable] Warning: Connector Ca is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GenericCombustion1D.mo:122:3-123:83:writable] Warning: Connector Cfg is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GenericCombustion1D.mo:124:3-126:17:writable] Warning: Connector Cws is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Splitter2.mo:24:3-26:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Splitter2.mo:27:3-28:82:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Splitter2.mo:29:3-31:17:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/Sink.mo:15:3-17:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/InvSingularPressureLoss.mo:19:3-21:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/InvSingularPressureLoss.mo:22:3-24:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:24:3-26:24:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:27:3-28:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:30:3-32:17:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticFluegasesFluegasesExchangerKS.mo:30:3-31:83:writable] Warning: Connector Sc is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticFluegasesFluegasesExchangerKS.mo:32:3-34:16:writable] Warning: Connector Ec is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticFluegasesFluegasesExchangerKS.mo:35:3-37:16:writable] Warning: Connector Ef is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticFluegasesFluegasesExchangerKS.mo:38:3-39:83:writable] Warning: Connector Sf is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourcePQ.mo:29:3-30:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/BoundaryConditions/FuelSourcePQ.mo:21:3-22:65:writable] Warning: Connector C is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:6:3-8:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:9:3-10:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:6:3-8:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:9:3-10:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:6:3-8:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:9:3-10:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/CheckValve.mo:38:3-39:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/CheckValve.mo:40:3-41:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:6:3-8:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:9:3-10:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01351/2.147, allocations: 4.117 MB / 0.8542 GB, free: 11.97 MB / 0.6231 GB Notification: Performance of NFTyping.typeBindings: time 0.03077/2.178, allocations: 10.39 MB / 0.8644 GB, free: 1.566 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.05418/2.232, allocations: 23.74 MB / 0.8875 GB, free: 9.867 MB / 0.6544 GB Notification: Performance of NFFlatten.flatten: time 0.05641/2.289, allocations: 54.48 MB / 0.9407 GB, free: 3.211 MB / 0.7012 GB Notification: Performance of NFFlatten.resolveConnections: time 0.02455/2.313, allocations: 18.44 MB / 0.9587 GB, free: 0.6367 MB / 0.7169 GB Notification: Performance of NFEvalConstants.evaluate: time 0.03231/2.346, allocations: 19.01 MB / 0.9773 GB, free: 13.57 MB / 0.7481 GB Notification: Performance of NFSimplifyModel.simplify: time 0.02939/2.375, allocations: 19.29 MB / 0.9961 GB, free: 10.21 MB / 0.7637 GB Notification: Performance of NFPackage.collectConstants: time 0.01465/2.39, allocations: 3.523 MB / 0.9996 GB, free: 6.688 MB / 0.7637 GB Notification: Performance of NFFlatten.collectFunctions: time 0.7109/3.101, allocations: 32.22 MB / 1.031 GB, free: 75.24 MB / 0.7638 GB Notification: Performance of NFScalarize.scalarize: time 0.01427/3.115, allocations: 9.957 MB / 1.041 GB, free: 75.24 MB / 0.7638 GB Notification: Performance of NFVerifyModel.verify: time 0.03492/3.15, allocations: 17.8 MB / 1.058 GB, free: 72.34 MB / 0.7638 GB Notification: Performance of NFConvertDAE.convert: time 0.08341/3.233, allocations: 56.33 MB / 1.113 GB, free: 58.47 MB / 0.7638 GB Notification: Performance of FrontEnd - DAE generated: time 7.484e-06/3.233, allocations: 1.344 kB / 1.113 GB, free: 58.47 MB / 0.7638 GB Notification: Performance of FrontEnd: time 1.843e-06/3.233, allocations: 0 / 1.113 GB, free: 58.47 MB / 0.7638 GB Notification: Performance of Transformations before backend: time 0.001539/3.235, allocations: 4.562 kB / 1.113 GB, free: 58.47 MB / 0.7638 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 8847 * Number of variables: 8847 Notification: Performance of Generate backend data structure: time 0.1128/3.348, allocations: 37.4 MB / 1.15 GB, free: 30.07 MB / 0.7638 GB Notification: Performance of prepare preOptimizeDAE: time 3.644e-05/3.348, allocations: 8.031 kB / 1.15 GB, free: 30.07 MB / 0.7638 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.01184/3.36, allocations: 3.129 MB / 1.153 GB, free: 26.9 MB / 0.7638 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.02032/3.38, allocations: 10.35 MB / 1.163 GB, free: 17.39 MB / 0.7638 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.006462/3.386, allocations: 7.014 MB / 1.17 GB, free: 9.371 MB / 0.7638 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.008318/3.395, allocations: 2.099 MB / 1.172 GB, free: 7.273 MB / 0.7638 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.09613/3.491, allocations: 44.57 MB / 1.215 GB, free: 9.574 MB / 0.8107 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0004679/3.491, allocations: 59.25 kB / 1.215 GB, free: 9.551 MB / 0.8107 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.005442/3.497, allocations: 0.864 MB / 1.216 GB, free: 8.688 MB / 0.8107 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001074/3.498, allocations: 1.296 MB / 1.217 GB, free: 7.391 MB / 0.8107 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.1071/3.605, allocations: 47.04 MB / 1.263 GB, free: 8.613 MB / 0.8575 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.6255/4.231, allocations: 193.6 MB / 1.452 GB, free: 161 MB / 0.92 GB Notification: Performance of preOpt comSubExp (simulation): time 0.0805/4.311, allocations: 39.36 MB / 1.491 GB, free: 144.8 MB / 0.92 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.05531/4.367, allocations: 29.71 MB / 1.52 GB, free: 127.5 MB / 0.92 GB Notification: Performance of preOpt evalFunc (simulation): time 0.5229/4.889, allocations: 186.6 MB / 1.702 GB, free: 451.6 MB / 0.9513 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.06381/4.953, allocations: 31.58 MB / 1.733 GB, free: 450.7 MB / 0.9513 GB Notification: Performance of pre-optimization done (n=5820): time 4.179e-05/4.953, allocations: 0 / 1.733 GB, free: 450.7 MB / 0.9513 GB Notification: Performance of matching and sorting (n=5830): time 0.8722/5.826, allocations: 274.4 MB / 2.001 GB, free: 211.3 MB / 0.9513 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002404/5.826, allocations: 1.056 MB / 2.002 GB, free: 210 MB / 0.9513 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.007033/5.833, allocations: 6.944 MB / 2.009 GB, free: 203.1 MB / 0.9513 GB Notification: Performance of collectPreVariables (initialization): time 0.006606/5.84, allocations: 425.7 kB / 2.009 GB, free: 202.7 MB / 0.9513 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/CheckValve.mo:7:3-8:32:writable] Warning: The parameter CheckValve.k has fixed = false and a binding equation CheckValve.k = 100.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:3:3-3:53:writable] Warning: The parameter singularPressureLoss_Eco.K has fixed = false and a binding equation singularPressureLoss_Eco.K = 3867.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_HP2.K has fixed = false and a binding equation lumpedStraightPipe_HP2.K = 1e-4, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:3:3-3:53:writable] Warning: The parameter singularPressureLoss_RBT.K has fixed = false and a binding equation singularPressureLoss_RBT.K = 34.39, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:3:3-3:53:writable] Warning: The parameter singularPressureLoss_SBT.K has fixed = false and a binding equation singularPressureLoss_SBT.K = 910.878, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:3:3-4:43:writable] Warning: The parameter controlValveIP.Cvmax has fixed = false and a binding equation controlValveIP.Cvmax = 8005.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:3:3-4:43:writable] Warning: The parameter controlValveHP.Cvmax has fixed = false and a binding equation controlValveHP.Cvmax = 8005.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_HP1.Cst has fixed = false and a binding equation Turbine_HP1.Cst = 279474.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_HP_IP.K has fixed = false and a binding equation lumpedStraightPipe_HP_IP.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_HP.K has fixed = false and a binding equation lumpedStraightPipe_HP.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_HP1.K has fixed = false and a binding equation lumpedStraightPipe_HP1.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:22:3-23:69:writable] Warning: The parameter staticCentrifugalPump1.a1 has fixed = false and a binding equation staticCentrifugalPump1.a1 = -3050.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_IP1.K has fixed = false and a binding equation lumpedStraightPipe_IP1.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:22:3-23:69:writable] Warning: The parameter staticCentrifugalPump.a1 has fixed = false and a binding equation staticCentrifugalPump.a1 = -390.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_LP3.K has fixed = false and a binding equation lumpedStraightPipe_LP3.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_LP2.K has fixed = false and a binding equation lumpedStraightPipe_LP2.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_LP1.K has fixed = false and a binding equation lumpedStraightPipe_LP1.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_IP3.K has fixed = false and a binding equation lumpedStraightPipe_IP3.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Echappement.Cst has fixed = false and a binding equation Echappement.Cst = 14.7, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_LP3.Cst has fixed = false and a binding equation Turbine_LP3.Cst = 59.4076, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_IP3.Cst has fixed = false and a binding equation Turbine_IP3.Cst = 34076.9, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_LP1.Cst has fixed = false and a binding equation Turbine_LP1.Cst = 4485.97, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_IP1.Cst has fixed = false and a binding equation Turbine_IP1.Cst = 102478.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_LP2.Cst has fixed = false and a binding equation Turbine_LP2.Cst = 1215.75, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_IP2.Cst has fixed = false and a binding equation Turbine_IP2.Cst = 53802.6, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_HP.Cst has fixed = false and a binding equation Turbine_HP.Cst = 2.00537e6, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. Notification: Performance of collectInitialEqns (initialization): time 0.003447/5.843, allocations: 6.302 MB / 2.015 GB, free: 196.4 MB / 0.9513 GB Notification: Performance of collectInitialBindings (initialization): time 0.0157/5.859, allocations: 19.1 MB / 2.034 GB, free: 177.5 MB / 0.9513 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.01725/5.876, allocations: 6.501 MB / 2.04 GB, free: 171 MB / 0.9513 GB Notification: Performance of setup shared object (initialization): time 4.121e-05/5.876, allocations: 305.1 kB / 2.041 GB, free: 170.7 MB / 0.9513 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.04797/5.924, allocations: 24.28 MB / 2.064 GB, free: 146.4 MB / 0.9513 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.05442/5.978, allocations: 30.07 MB / 2.094 GB, free: 114.8 MB / 0.9513 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 1.804/7.782, allocations: 0.621 GB / 2.715 GB, free: 335.5 MB / 0.9513 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.000101/7.782, allocations: 28 kB / 2.715 GB, free: 335.5 MB / 0.9513 GB Notification: Performance of matching and sorting (n=6510) (initialization): time 0.1851/7.967, allocations: 84.63 MB / 2.797 GB, free: 253.8 MB / 0.9513 GB Notification: Performance of prepare postOptimizeDAE: time 0.0001589/7.968, allocations: 111.2 kB / 2.797 GB, free: 253.7 MB / 0.9513 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0003673/7.968, allocations: 161 kB / 2.798 GB, free: 253.6 MB / 0.9513 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.712/9.68, allocations: 0.8337 GB / 3.631 GB, free: 404 MB / 0.9513 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.007399/9.688, allocations: 1.789 MB / 3.633 GB, free: 404 MB / 0.9513 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.01703/9.705, allocations: 14.47 MB / 3.647 GB, free: 393.4 MB / 0.9513 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.02766/9.732, allocations: 2.8 MB / 3.65 GB, free: 393.4 MB / 0.9513 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.004212/9.737, allocations: 1.245 MB / 3.651 GB, free: 393.4 MB / 0.9513 GB Warning: Assuming fixed start value for the following 4 variables: TemperatureControl.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Level_Condenser.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Level_Condenser.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Pump_VelocityControl.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 30 initial equations are redundant, so they are removed from the initialization system: $DER.splitter_TurbineIP2.P = 0.0 $DER.splitter_Turbine_HP.P = 0.0 $DER.Boiler_walls.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.RMT_RHT.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SBT.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.RBT.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.RBT.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.Economiseur.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SMT_SHT.TwoPhaseFlowPipe.Q[3] = 0.0 $DER.SMT_SHT.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.TemperatureControl.pIsat.Integrateur1.x = 0.0 $DER.volume_HP2.h = 0.0 $DER.volume_HP1Vap1.P = 0.0 $DER.volume_HP21.P = 0.0 $DER.volume_HP21.h = 0.0 $DER.pT1_2.x = 0.0 CheckValve.Q = $START.CheckValve.Q SMT_SHT.TwoPhaseFlowPipe.P[5] = $START.SMT_SHT.TwoPhaseFlowPipe.P[5] RMT_RHT.TwoPhaseFlowPipe.P[5] = $START.RMT_RHT.TwoPhaseFlowPipe.P[5] lumpedStraightPipe_HP_IP.Q = $START.lumpedStraightPipe_HP_IP.Q lumpedStraightPipe_LP3.Q = $START.lumpedStraightPipe_LP3.Q splitter_TurbineLP3.P = $START.splitter_TurbineLP3.P lumpedStraightPipe_LP2.Q = $START.lumpedStraightPipe_LP2.Q splitter_TurbineLP2.P = $START.splitter_TurbineLP2.P splitter_TurbineLP1.P = $START.splitter_TurbineLP1.P splitter_TurbineIP3.P = $START.splitter_TurbineIP3.P lumpedStraightPipe_IP3.Q = $START.lumpedStraightPipe_IP3.Q splitter_TurbineIP2.P = $START.splitter_TurbineIP2.P splitter_TurbineIP1.P = $START.splitter_TurbineIP1.P Turbine_HP.Pe = $START.Turbine_HP.Pe. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 493 * Number of states: 0 () * Number of discrete variables: 348 ($PRE.TemperatureControl.pIsat.Integrateur1.x0,TemperatureControl.pIsat.Integrateur1.x0,$PRE.regulation_Level_Condenser.pIsat.Integrateur1.x0,regulation_Level_Condenser.pIsat.Integrateur1.x0,$PRE.regulation_Level_Condenser.pIsat1.Integrateur1.x0,regulation_Level_Condenser.pIsat1.Integrateur1.x0,$PRE.Pump_VelocityControl.pIsat.Integrateur1.x0,Pump_VelocityControl.pIsat.Integrateur1.x0,$PRE.CheckValve.touvert,$whenCondition2,$PRE.CheckValve.tferme,$whenCondition1,Pump_VelocityControl.pIsat.Integrateur1.reset.signal,regulation_Level_Condenser.pIsat.Integrateur1.reset.signal,TemperatureControl.pIsat.Integrateur1.reset.signal,CheckValve.tferme,CheckValve.touvert,CheckValve.ouvert,$PRE.CheckValve.ouvert,regulation_Level_Condenser.echelon.yL.signal,regulation_Level_Condenser.edge.yL.signal,regulation_Level_Condenser.edge.uL.signal,$PRE.regulation_Level_Condenser.edge.uL.signal,$whenCondition3,volume_HP22.Cs2.b,volume_HP22.Cs1.b,volume_HP22.Ce2.a,volume_HP22.Ce1.a,volume_HP21.Cs2.b,volume_HP21.Cs1.b,volume_HP21.Ce2.a,volume_HP21.Ce1.a,singularPressureLoss7.C2.b,singularPressureLoss7.C1.a,singularPressureLoss6.C2.b,singularPressureLoss6.C1.a,singularPressureLoss5.C2.b,singularPressureLoss5.C1.a,singularPressureLoss4.C2.b,singularPressureLoss4.C1.a,singularPressureLoss3.C2.b,singularPressureLoss3.C1.a,singularPressureLoss2.C2.b,singularPressureLoss2.C1.a,singularPressureLoss1.C2.b,singularPressureLoss1.C1.a,volume_HP1Vap1.Cs2.b,volume_HP1Vap1.Cs1.b,volume_HP1Vap1.Ce2.a,volume_HP1Vap1.Ce1.a,volume_HP1Vap.Cs2.b,volume_HP1Vap.Cs1.b,volume_HP1Vap.Ce2.a,volume_HP1Vap.Ce1.a,volume_HP3.Cs2.b,volume_HP3.Cs1.b,volume_HP3.Ce2.a,volume_HP3.Ce1.a,volume_HP2.Cs2.b,volume_HP2.Cs1.b,volume_HP2.Ce2.a,volume_HP2.Ce1.a,ReheaterHP2_1.Ev.a,ReheaterHP2_1.Sp.b,ReheaterHP2_1.Ep.a,ReheaterHP2_1.Se.b,ReheaterHP2_1.Ee.a,ReheaterHP1_1.Ev.a,ReheaterHP1_1.Sp.b,ReheaterHP1_1.Ep.a,ReheaterHP1_1.Se.b,ReheaterHP1_1.Ee.a,volume_HP1.Cs2.b,volume_HP1.Cs1.b,volume_HP1.Ce2.a,volume_HP1.Ce1.a,sensorQ.C2.b,sensorQ.C1.a,CheckValve.C2.b,CheckValve.C1.a,singularPressureLoss_Eco.C2.b,singularPressureLoss_Eco.C1.a,splitter_condenser.Cs2.b,splitter_condenser.Cs1.b,splitter_condenser.Ce2.a,splitter_condenser.Ce1.a,lumpedStraightPipe_HP2.C2.b,lumpedStraightPipe_HP2.C1.a,lumpedStraightPipe_Condenser1.C2.b,lumpedStraightPipe_Condenser1.C1.a,controlValve_Condenser.C2.b,controlValve_Condenser.C1.a,lumpedStraightPipe_Low.C2.b,lumpedStraightPipe_Low.C1.a,Sensor_Qvap_Cond2.C2.b,Sensor_Qvap_Cond2.C1.a,Sensor_Qvap_Cond.C2.b,Sensor_Qvap_Cond.C1.a,loopBreakerP_Cond.C2.b,loopBreakerP_Cond.C1.a,loopBreakerP_ReDrum.C2.b,loopBreakerP_ReDrum.C1.a,loopBreakerP_Drum_2.C2.b,loopBreakerP_Drum_2.C1.a,controlValveEco.C2.b,controlValveEco.C1.a,fuelSourcePQ.C.b,sourceQ.C.b,volumeA.Cs2.b,volumeA.Cs1.b,volumeA.Ce2.a,volumeA.Ce1.a,volumeA1.Cs2.b,volumeA1.Cs1.b,volumeA1.Ce2.a,volumeA1.Ce1.a,AirPreheater.Ce2.a,AirPreheater.Cs1.b,AirPreheater.Cs2.b,AirPreheater.Ce1.a,sourceAir.C.b,RA.Sf.b,RA.Ef.a,RA.Ec.a,RA.Sc.b,mixer2_1.Ce1.a,mixer2_1.Cs.b,mixer2_1.Ce2.a,singularPressureLoss.C2.b,singularPressureLoss.C1.a,SMT_SHT.TwoPhaseFlowPipe.C2.b,SMT_SHT.TwoPhaseFlowPipe.C1.a,SMT_SHT.ExchangerFlueGasesMetal.C2.b,SMT_SHT.ExchangerFlueGasesMetal.C1.a,Economiseur.TwoPhaseFlowPipe.C2.b,Economiseur.TwoPhaseFlowPipe.C1.a,Economiseur.ExchangerFlueGasesMetal.C2.b,Economiseur.ExchangerFlueGasesMetal.C1.a,singularPressureLoss_RBT.C2.b,singularPressureLoss_RBT.C1.a,RBT.TwoPhaseFlowPipe.C2.b,RBT.TwoPhaseFlowPipe.C1.a,RBT.ExchangerFlueGasesMetal.C2.b,RBT.ExchangerFlueGasesMetal.C1.a,singularPressureLoss_SBT.C2.b,singularPressureLoss_SBT.C1.a,SBT.TwoPhaseFlowPipe.C2.b,SBT.TwoPhaseFlowPipe.C1.a,SBT.ExchangerFlueGasesMetal.C2.b,SBT.ExchangerFlueGasesMetal.C1.a,RMT_RHT.TwoPhaseFlowPipe.C2.b,RMT_RHT.TwoPhaseFlowPipe.C1.a,RMT_RHT.ExchangerFlueGasesMetal.C2.b,RMT_RHT.ExchangerFlueGasesMetal.C1.a,puitsFumeesPTQXA1.C.a,Boiler_walls.TwoPhaseFlowPipe.C2.b,Boiler_walls.TwoPhaseFlowPipe.C1.a,Boiler_walls.ExchangerFlueGasesMetal.C2.b,Boiler_walls.ExchangerFlueGasesMetal.C1.a,splitter2_1.Cs2.b,splitter2_1.Cs1.b,splitter2_1.Ce.a,Wall_screen.C2.b,Wall_screen.C1.a,genericCombustion.Cws.a,genericCombustion.Cfg.b,genericCombustion.Ca.a,genericCombustion.Cfuel.a,controlValveIP.C2.b,controlValveIP.C1.a,controlValveHP.C2.b,controlValveHP.C1.a,sensorT.C2.b,sensorT.C1.a,splitter_Turbine_HP.Cs3.b,splitter_Turbine_HP.Cs2.b,splitter_Turbine_HP.Cs1.b,splitter_Turbine_HP.Ce.a,Turbine_HP1.Cs.b,Turbine_HP1.Ce.a,lumpedStraightPipe_HP_IP.C2.b,lumpedStraightPipe_HP_IP.C1.a,lumpedStraightPipe_HP.C2.b,lumpedStraightPipe_HP.C1.a,Desuperheater.Sc.b,Desuperheater.Sf.b,Desuperheater.Ef.a,Desuperheater.Ec.a,ReheaterHP1.Ev.a,ReheaterHP1.Sp.b,ReheaterHP1.Ep.a,ReheaterHP1.Se.b,ReheaterHP1.Ee.a,lumpedStraightPipe_HP1.C2.b,lumpedStraightPipe_HP1.C1.a,ReheaterHP2.Ev.a,ReheaterHP2.Sp.b,ReheaterHP2.Ep.a,ReheaterHP2.Se.b,ReheaterHP2.Ee.a,lumpedStraightPipe_Desu.C2.b,lumpedStraightPipe_Desu.C1.a,ReheaterHP3.Ev.a,ReheaterHP3.Sp.b,ReheaterHP3.Ep.a,ReheaterHP3.Se.b,ReheaterHP3.Ee.a,staticCentrifugalPump1.C2.b,staticCentrifugalPump1.C1.a,Drum_2.Cs3.b,Drum_2.Cs2.b,Drum_2.Cs1.b,Drum_2.Cs4.b,Drum_2.Ce1.a,Drum_2.Ce4.a,Drum_2.Ce3.a,Drum_2.Ce2.a,lumpedStraightPipe_IP1.C2.b,lumpedStraightPipe_IP1.C1.a,Drum_1.Cs3.b,Drum_1.Cs2.b,Drum_1.Cs1.b,Drum_1.Cs4.b,Drum_1.Ce1.a,Drum_1.Ce4.a,Drum_1.Ce3.a,Drum_1.Ce2.a,pipePressureLoss_LP3_Drum.C2.b,pipePressureLoss_LP3_Drum.C1.a,ReheaterIP.Ev.a,ReheaterIP.Sp.b,ReheaterIP.Ep.a,ReheaterIP.Se.b,ReheaterIP.Ee.a,ReheaterLP1.Ev.a,ReheaterLP1.Sp.b,ReheaterLP1.Ep.a,ReheaterLP1.Se.b,ReheaterLP1.Ee.a,ReheaterLP2.Ev.a,ReheaterLP2.Sp.b,ReheaterLP2.Ep.a,ReheaterLP2.Se.b,ReheaterLP2.Ee.a,ReheaterLP3.Ev.a,ReheaterLP3.Sp.b,ReheaterLP3.Ep.a,ReheaterLP3.Se.b,ReheaterLP3.Ee.a,ReDrum.Sc.b,ReDrum.Sf.b,ReDrum.Ef.a,ReDrum.Ec.a,staticCentrifugalPump.C2.b,staticCentrifugalPump.C1.a,Condenser.Cse.b,Condenser.Cee.a,Condenser.Cl.b,Condenser.Cv.a,lumpedStraightPipe_Condenser2.C2.b,lumpedStraightPipe_Condenser2.C1.a,SourceCaloporteur.C.b,PuitsCaloporteur.C.a,lumpedStraightPipe_LP3.C2.b,lumpedStraightPipe_LP3.C1.a,splitter_TurbineLP3.Cs2.b,splitter_TurbineLP3.Cs1.b,splitter_TurbineLP3.Ce2.a,splitter_TurbineLP3.Ce1.a,lumpedStraightPipe_LP2.C2.b,lumpedStraightPipe_LP2.C1.a,splitter_TurbineLP2.Cs2.b,splitter_TurbineLP2.Cs1.b,splitter_TurbineLP2.Ce2.a,splitter_TurbineLP2.Ce1.a,lumpedStraightPipe_LP1.C2.b,lumpedStraightPipe_LP1.C1.a,splitter_TurbineLP1.Cs2.b,splitter_TurbineLP1.Cs1.b,splitter_TurbineLP1.Ce2.a,splitter_TurbineLP1.Ce1.a,splitter_TurbineIP3.Cs2.b,splitter_TurbineIP3.Cs1.b,splitter_TurbineIP3.Ce2.a,splitter_TurbineIP3.Ce1.a,lumpedStraightPipe_IP3.C2.b,lumpedStraightPipe_IP3.C1.a,splitter_TurbineIP2.Cs2.b,splitter_TurbineIP2.Cs1.b,splitter_TurbineIP2.Ce2.a,splitter_TurbineIP2.Ce1.a,splitter_TurbineIP1.Cs2.b,splitter_TurbineIP1.Cs1.b,splitter_TurbineIP1.Ce2.a,splitter_TurbineIP1.Ce1.a,Echappement.Cs.b,Echappement.Ce.a,Turbine_LP3.Cs.b,Turbine_LP3.Ce.a,Turbine_IP3.Cs.b,Turbine_IP3.Ce.a,Turbine_LP1.Cs.b,Turbine_LP1.Ce.a,Turbine_IP1.Cs.b,Turbine_IP1.Ce.a,Turbine_LP2.Cs.b,Turbine_LP2.Ce.a,Turbine_IP2.Cs.b,Turbine_IP2.Ce.a,splitter_Turbine_HP1.Cs3.b,splitter_Turbine_HP1.Cs2.b,splitter_Turbine_HP1.Cs1.b,splitter_Turbine_HP1.Ce.a,Turbine_HP.Cs.b,Turbine_HP.Ce.a,volume_HP22.Cs2.a,volume_HP22.Ce2.b,volume_HP21.Cs2.a,volume_HP21.Ce2.b,volume_HP1Vap1.Ce2.b,volume_HP1Vap.Ce2.b,volume_HP3.Cs1.a,volume_HP2.Ce1.b,ReheaterHP1_1.Ep.b,volume_HP1.Cs1.a,splitter_condenser.Cs2.a,volumeA.Cs2.a,volumeA1.Ce2.b,AirPreheater.Cs2.a,AirPreheater.Ce2.b,splitter_Turbine_HP.Cs1.a,ReheaterHP1.Ep.b,Drum_2.Cs4.a,Drum_2.Cs3.a,Drum_2.Cs2.a,Drum_2.Ce3.b,Drum_1.Cs4.a,Drum_1.Cs3.a,Drum_1.Cs2.a,Drum_1.Ce4.b,Drum_1.Ce2.b,ReheaterIP.Ep.b,ReheaterLP3.Ep.b,splitter_TurbineLP3.Ce2.b,splitter_TurbineLP2.Ce2.b,splitter_TurbineLP1.Ce2.b,splitter_TurbineIP2.Ce2.b,splitter_TurbineIP1.Ce2.b) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1102): * Single equations (assignments): 988 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 98 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 3 * Torn equation systems: 11 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 1 system {(2,100.0%)} * Non-linear Jacobian (size): 2 systems {1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 2 systems {(4,1,62.5%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 9 systems {(1,4), (1,3), (1,3), (1,3), (1,3), (276,1631), (1,1), (9,3), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.01353/9.75, allocations: 5.564 MB / 3.657 GB, free: 393.2 MB / 0.9513 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.005843/9.756, allocations: 2.155 MB / 3.659 GB, free: 393.2 MB / 0.9513 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.1931/9.949, allocations: 102.2 MB / 3.758 GB, free: 366 MB / 0.9513 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.1797/10.13, allocations: 86.98 MB / 3.843 GB, free: 315 MB / 0.9513 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002008/10.13, allocations: 12 kB / 3.843 GB, free: 315 MB / 0.9513 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.0008172/10.13, allocations: 204.7 kB / 3.844 GB, free: 315 MB / 0.9513 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.3584/10.49, allocations: 163.9 MB / 4.004 GB, free: 154.8 MB / 0.9513 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0007838/10.49, allocations: 56.19 kB / 4.004 GB, free: 154.7 MB / 0.9513 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.04095/10.53, allocations: 8.952 MB / 4.012 GB, free: 146 MB / 0.9513 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.3692/10.9, allocations: 56.63 MB / 4.068 GB, free: 412.2 MB / 0.9513 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.01005/10.91, allocations: 1.178 MB / 4.069 GB, free: 412.2 MB / 0.9513 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.1876/11.1, allocations: 171.6 MB / 4.236 GB, free: 300.9 MB / 0.9513 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 3.717e-06/11.1, allocations: 2.688 kB / 4.236 GB, free: 300.9 MB / 0.9513 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.2971/11.39, allocations: 128.7 MB / 4.362 GB, free: 211.6 MB / 0.9513 GB Notification: Performance of postOpt removeConstants (simulation): time 0.02212/11.42, allocations: 7.209 MB / 4.369 GB, free: 205.3 MB / 0.9513 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.01128/11.43, allocations: 0.8103 MB / 4.37 GB, free: 204.5 MB / 0.9513 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.032/11.46, allocations: 2.879 MB / 4.373 GB, free: 201.7 MB / 0.9513 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.01227/11.47, allocations: 2.778 MB / 4.375 GB, free: 198.9 MB / 0.9513 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.008807/11.48, allocations: 1.335 MB / 4.377 GB, free: 197.6 MB / 0.9513 GB Notification: Performance of sorting global known variables: time 0.006907/11.49, allocations: 4.212 MB / 4.381 GB, free: 193.4 MB / 0.9513 GB Notification: Performance of sort global known variables: time 2.81e-07/11.49, allocations: 0 / 4.381 GB, free: 193.4 MB / 0.9513 GB Notification: Performance of remove unused functions: time 0.04028/11.53, allocations: 11.24 MB / 4.392 GB, free: 182.5 MB / 0.9513 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 8 * Number of states: 152 (splitter_Turbine_HP1.P,splitter_Turbine_HP1.h,splitter_TurbineIP1.h,splitter_TurbineIP2.P,splitter_TurbineIP2.h,splitter_TurbineIP3.h,splitter_TurbineLP1.h,splitter_TurbineLP2.h,splitter_TurbineLP3.h,Condenser.P,Condenser.hl,Condenser.hv,Condenser.Vv,Drum_1.h,Drum_2.h,splitter_Turbine_HP.P,splitter_Turbine_HP.h,Wall_screen.P[2],Wall_screen.P[3],Wall_screen.P[4],Wall_screen.P[5],Wall_screen.P[6],Wall_screen.P[7],Wall_screen.P[8],Wall_screen.Q[1],Wall_screen.Q[2],Wall_screen.Q[3],Wall_screen.Q[4],Wall_screen.Q[5],Wall_screen.Q[6],Wall_screen.Q[7],Wall_screen.h[2],Wall_screen.h[3],Wall_screen.h[4],Wall_screen.h[5],Wall_screen.h[6],Wall_screen.h[7],Wall_screen.h[8],heatExchangerWall.Tp[1],heatExchangerWall.Tp[2],heatExchangerWall.Tp[3],heatExchangerWall.Tp[4],heatExchangerWall.Tp[5],heatExchangerWall.Tp[6],heatExchangerWall.Tp[7],Boiler_walls.ExchangerWall.Tp[1],Boiler_walls.ExchangerWall.Tp[2],Boiler_walls.ExchangerWall.Tp[3],Boiler_walls.TwoPhaseFlowPipe.P[2],Boiler_walls.TwoPhaseFlowPipe.P[3],Boiler_walls.TwoPhaseFlowPipe.P[4],Boiler_walls.TwoPhaseFlowPipe.Q[1],Boiler_walls.TwoPhaseFlowPipe.Q[2],Boiler_walls.TwoPhaseFlowPipe.Q[3],Boiler_walls.TwoPhaseFlowPipe.h[2],Boiler_walls.TwoPhaseFlowPipe.h[3],Boiler_walls.TwoPhaseFlowPipe.h[4],RMT_RHT.ExchangerWall.Tp[1],RMT_RHT.ExchangerWall.Tp[2],RMT_RHT.ExchangerWall.Tp[3],RMT_RHT.TwoPhaseFlowPipe.P[2],RMT_RHT.TwoPhaseFlowPipe.P[3],RMT_RHT.TwoPhaseFlowPipe.P[4],RMT_RHT.TwoPhaseFlowPipe.Q[2],RMT_RHT.TwoPhaseFlowPipe.Q[3],RMT_RHT.TwoPhaseFlowPipe.Q[4],RMT_RHT.TwoPhaseFlowPipe.h[2],RMT_RHT.TwoPhaseFlowPipe.h[3],RMT_RHT.TwoPhaseFlowPipe.h[4],SBT.ExchangerWall.Tp[1],SBT.ExchangerWall.Tp[2],SBT.ExchangerWall.Tp[3],SBT.TwoPhaseFlowPipe.P[2],SBT.TwoPhaseFlowPipe.P[3],SBT.TwoPhaseFlowPipe.P[4],SBT.TwoPhaseFlowPipe.Q[1],SBT.TwoPhaseFlowPipe.Q[2],SBT.TwoPhaseFlowPipe.Q[3],SBT.TwoPhaseFlowPipe.Q[4],SBT.TwoPhaseFlowPipe.h[2],SBT.TwoPhaseFlowPipe.h[3],SBT.TwoPhaseFlowPipe.h[4],RBT.ExchangerWall.Tp[1],RBT.ExchangerWall.Tp[2],RBT.ExchangerWall.Tp[3],RBT.TwoPhaseFlowPipe.P[2],RBT.TwoPhaseFlowPipe.P[3],RBT.TwoPhaseFlowPipe.P[4],RBT.TwoPhaseFlowPipe.Q[1],RBT.TwoPhaseFlowPipe.Q[2],RBT.TwoPhaseFlowPipe.Q[3],RBT.TwoPhaseFlowPipe.Q[4],RBT.TwoPhaseFlowPipe.h[2],RBT.TwoPhaseFlowPipe.h[3],RBT.TwoPhaseFlowPipe.h[4],Economiseur.ExchangerWall.Tp[1],Economiseur.ExchangerWall.Tp[2],Economiseur.ExchangerWall.Tp[3],Economiseur.TwoPhaseFlowPipe.P[2],Economiseur.TwoPhaseFlowPipe.P[3],Economiseur.TwoPhaseFlowPipe.P[4],Economiseur.TwoPhaseFlowPipe.Q[1],Economiseur.TwoPhaseFlowPipe.Q[2],Economiseur.TwoPhaseFlowPipe.Q[3],Economiseur.TwoPhaseFlowPipe.Q[4],Economiseur.TwoPhaseFlowPipe.h[2],Economiseur.TwoPhaseFlowPipe.h[3],Economiseur.TwoPhaseFlowPipe.h[4],SMT_SHT.ExchangerWall.Tp[1],SMT_SHT.ExchangerWall.Tp[2],SMT_SHT.ExchangerWall.Tp[3],SMT_SHT.TwoPhaseFlowPipe.P[2],SMT_SHT.TwoPhaseFlowPipe.P[3],SMT_SHT.TwoPhaseFlowPipe.P[4],SMT_SHT.TwoPhaseFlowPipe.Q[1],SMT_SHT.TwoPhaseFlowPipe.Q[2],SMT_SHT.TwoPhaseFlowPipe.Q[3],SMT_SHT.TwoPhaseFlowPipe.Q[4],SMT_SHT.TwoPhaseFlowPipe.h[2],SMT_SHT.TwoPhaseFlowPipe.h[3],SMT_SHT.TwoPhaseFlowPipe.h[4],AirPreheater.Xh2o,volumeA1.h,volumeA.P,volumeA.h,TemperatureControl.pIsat.Integrateur1.x,TemperatureControl.pT1_1.x,regulation_Level_Condenser.pIsat.Integrateur1.x,regulation_Level_Condenser.pIsat1.Integrateur1.x,regulation_Level_Condenser.pT1_1.x,regulation_Level_Condenser.pT1_2.x,regulation_Level_Condenser.pT1_3.x,splitter_condenser.h,Pump_VelocityControl.pIsat.Integrateur1.x,Pump_VelocityControl.pT1_1.x,pT1_1.x,volume_HP1.P,volume_HP1.h,volume_HP2.P,volume_HP2.h,volume_HP3.h,volume_HP1Vap.P,volume_HP1Vap.h,volume_HP1Vap1.P,volume_HP1Vap1.h,volume_HP21.P,volume_HP21.h,volume_HP22.P,volume_HP22.h,pT1_3.x,pT1_4.x,pT1_5.x) * Number of discrete variables: 13 ($whenCondition3,$whenCondition2,$whenCondition1,TemperatureControl.pIsat.Integrateur1.x0,regulation_Level_Condenser.pIsat.Integrateur1.x0,regulation_Level_Condenser.pIsat1.Integrateur1.x0,regulation_Level_Condenser.edge.uL.signal,regulation_Level_Condenser.edge.yL.signal,regulation_Level_Condenser.echelon.yL.signal,CheckValve.ouvert,CheckValve.touvert,CheckValve.tferme,Pump_VelocityControl.pIsat.Integrateur1.x0) * Number of discrete states: 5 (CheckValve.touvert,CheckValve.tferme,regulation_Level_Condenser.echelon.yL.signal,regulation_Level_Condenser.edge.yL.signal,regulation_Level_Condenser.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (3410): * Single equations (assignments): 3106 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 186 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 10 * Torn equation systems: 101 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 10 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 42 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 59 systems {(1,2), (1,2), (1,2), (1,2), (1,4), (1,3), (1,2), (1,2), (1,2), (1,2), (1,2), (1,2), (1,5), (1,2), (1,2), (1,2), (1,2), (1,3), (1,1), (1,3), (80,211), (1,6), (3,7), (1,2), (1,2), (1,3), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,3), (1,6), (1,6), (1,6), (2,37), (1,6), (1,6), (1,6), (1,6), (1,6), (1,5), (1,3), (52,195), (19,42), (1,3), (1,26), (1,2), (1,2), (1,1), (1,5), (1,5), (1,3), (19,42)} Notification: Performance of Backend phase and start with SimCode phase: time 0.02015/11.55, allocations: 4.38 MB / 4.396 GB, free: 179.3 MB / 0.9513 GB Notification: Performance of simCode: created initialization part: time 0.1829/11.73, allocations: 117 MB / 4.51 GB, free: 58.11 MB / 0.9513 GB Notification: Performance of simCode: created event and clocks part: time 9.127e-06/11.73, allocations: 4 kB / 4.51 GB, free: 58.11 MB / 0.9513 GB Notification: Performance of simCode: created simulation system equations: time 0.1053/11.84, allocations: 55.93 MB / 4.565 GB, free: 1.23 MB / 0.9513 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.3386/12.18, allocations: 13.94 MB / 4.579 GB, free: 402.5 MB / 0.9513 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.2313/12.41, allocations: 101.7 MB / 4.678 GB, free: 379.1 MB / 0.9513 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.02848/12.44, allocations: 17.16 MB / 4.695 GB, free: 377.2 MB / 0.9513 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.01262/12.45, allocations: 1.921 MB / 4.697 GB, free: 377.2 MB / 0.9513 GB Notification: Performance of SimCode: time 8.11e-07/12.45, allocations: 0 / 4.697 GB, free: 377.2 MB / 0.9513 GB Notification: Performance of Templates: time 15.09/27.54, allocations: 9.105 GB / 13.8 GB, free: 332.3 MB / 0.9514 GB make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant.makefile make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/include/omc/sundials" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.o OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.cpp In file included from OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.cpp:25: In file included from ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgLoopMain.cpp:45: ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:85:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp1251.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:86:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp1251.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:87:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp1251.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:88:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp1251.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:89:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp1251.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:90:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_pt_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_pt_ = get<0>(tmp1251.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:91:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_cv_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_cv_ = get<0>(tmp1251.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:92:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_P_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_P_ = get<1>(tmp1251.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:93:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_T_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_T_ = get<1>(tmp1251.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:94:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_rho_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_rho_ = get<1>(tmp1251.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:95:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_h_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_h_ = get<1>(tmp1251.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:96:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_cp_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_cp_ = get<1>(tmp1251.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:97:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_pt_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_pt_ = get<1>(tmp1251.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:98:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_cv_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_cv_ = get<1>(tmp1251.data).cv_; ^ In file included from OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.cpp:25: In file included from ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgLoopMain.cpp:120: ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:95:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp1497.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:96:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp1497.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:97:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp1497.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:98:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp1497.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:99:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp1497.data).cp_; ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. make: *** [: OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.o] Error 1