Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.CO2PB.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo", uses=false) Using package SolarTherm with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.CO2PB,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.CO2PB") translateModel(SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.CO2PB,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.CO2PB") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001432/0.001432, allocations: 104.2 kB / 16.4 MB, free: 6.465 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001874/0.001875, allocations: 192.2 kB / 17.34 MB, free: 5.719 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.693/1.693, allocations: 205.1 MB / 223.2 MB, free: 12.23 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo): time 0.1168/0.1168, allocations: 24.84 MB / 295.4 MB, free: 3.148 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001732/0.001732, allocations: 67.12 kB / 413 MB, free: 33.44 MB / 318.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1134/0.1151, allocations: 52.3 MB / 465.3 MB, free: 13.14 MB / 350.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/Models/PowerBlocks/sCO2Cycle/OffDesign/CO2PB.mo:27:3-27:186:writable] Error: Class SolarTherm.Types.Conductance not found in scope CO2PB. Notification: Performance of FrontEnd: time 0.00346/0.1186, allocations: 1.632 MB / 466.9 MB, free: 11.49 MB / 350.1 MB