Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus") translateModel(Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.EquationFitReversible_EnergyPlus") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.473/1.473, allocations: 251.5 MB / 267.4 MB, free: 11.06 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001041/0.001041, allocations: 170.8 kB / 326.5 MB, free: 2.684 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.578/1.578, allocations: 205 MB / 0.5766 GB, free: 21.02 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007774/0.0007774, allocations: 103.9 kB / 0.6804 GB, free: 14.71 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0005275/0.0005278, allocations: 12.98 kB / 0.7938 GB, free: 136.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.236/0.2365, allocations: 105.4 MB / 0.8967 GB, free: 68.17 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/HeatPumps/Data/EquationFitReversible/Generic.mo:21:3-51:25:writable] Error: Protected sections are not allowed in record. Notification: Performance of FrontEnd: time 0.04519/0.2818, allocations: 61.4 MB / 0.9567 GB, free: 6.559 MB / 0.6042 GB