Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00133/0.00133, allocations: 104.2 kB / 19.74 MB, free: 2.07 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001483/0.001483, allocations: 207.2 kB / 23.03 MB, free: 4.863 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.446/1.446, allocations: 230.6 MB / 256.8 MB, free: 7.793 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo): time 3.108/3.108, allocations: 0.49 GB / 0.7959 GB, free: 35.55 MB / 0.6231 GB " [Timeout remaining time 177] Using package Buildings with version 12.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|bus.hrc.y1|bus.hrc.y1Coo|bus.pumChiWatHrc.y1|bus.pumHeaWatHrc.y1|TChiWatLvg.T|inlChiWat.T|TSupSet.y|THeaWatLvg.T|inlHeaWat.T|hrc.hrc.chi.PLR2|hrc.hrc.chi.COP",fileNamePrefix="Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller") translateModel(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|bus.hrc.y1|bus.hrc.y1Coo|bus.pumChiWatHrc.y1|bus.pumHeaWatHrc.y1|TChiWatLvg.T|inlChiWat.T|TSupSet.y|THeaWatLvg.T|inlHeaWat.T|hrc.hrc.chi.PLR2|hrc.hrc.chi.COP",fileNamePrefix="Buildings_12_Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.00208/0.00208, allocations: 72.61 kB / 1.155 GB, free: 25.23 MB / 0.9044 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.332/0.334, allocations: 176.1 MB / 1.327 GB, free: 0.9727 MB / 1.014 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Plants.HeatPumps.Components.Validation.HeatRecoveryChiller): time 0.1495/0.4835, allocations: 130.5 MB / 1.455 GB, free: 14.07 MB / 1.154 GB Notification: Performance of NFInst.instExpressions: time 0.06262/0.5461, allocations: 39.72 MB / 1.493 GB, free: 6.258 MB / 1.186 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.007509/0.5536, allocations: 258.1 kB / 1.494 GB, free: 6.004 MB / 1.186 GB Notification: Performance of NFTyping.typeComponents: time 0.01314/0.5668, allocations: 4.496 MB / 1.498 GB, free: 1.492 MB / 1.186 GB Notification: Performance of NFTyping.typeBindings: time 0.0191/0.5859, allocations: 7.001 MB / 1.505 GB, free: 10.46 MB / 1.201 GB Notification: Performance of NFTyping.typeClassSections: time 0.01272/0.5986, allocations: 5.114 MB / 1.51 GB, free: 5.367 MB / 1.201 GB Notification: Performance of NFFlatten.flatten: time 0.04501/0.6436, allocations: 31.51 MB / 1.541 GB, free: 5.805 MB / 1.232 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Templates/Plants/HeatPumps/Components/Validation/HeatRecoveryChiller.mo:154:3-155:89:writable] Error: Cannot connect expandable connector busPumHeaWatHrc with non-expandable connector bus.pumHeaWatHrc. Notification: Performance of FrontEnd: time 0.00182/0.6454, allocations: 0.724 MB / 1.541 GB, free: 5.031 MB / 1.232 GB " [Timeout remaining time 299] [Calling sys.exit(0), Time elapsed: 6.8982628411613405] Failed to read output from testmodel.py, exit status != 0: 0.6526505099609494 0.666385662 -1.0 Calling exit ...