startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2 -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Using pre-compiled FMU /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 9.0.0-master/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones3.fmu stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2/EnergyPlus-simulation-Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2/Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2.fmu. It will not be converted to SI units. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2/EnergyPlus-simulation-Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2/Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2.fmu. It will not be converted to SI units. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning from EnergyPlus: "*** Test warning written by Zones3.core.&##10;" stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning from EnergyPlus: "*** Test warning written by Zones3.north.&##10;" stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones2: Warning from EnergyPlus: "*** Test warning written by Zones3.south.&##10;" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00411905s reading init.xml | | | | | | 0.000435978s reading info.xml | | | | | | 5.2959e-05s [ 0.1%] pre-initialization | | | | | | 0.0437325s [ 75.1%] initialization | | | | | | 1.653e-06s [ 0.0%] steps | | | | | | 0.00112291s [ 1.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00248071s [ 4.3%] event-handling | | | | | | 0.0029636s [ 5.1%] overhead | | | | | | 0.00789906s [ 13.6%] simulation | | | | | | 0.0582534s [100.0%] total | | | | | events | | | | | | 59 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 1040 steps taken | | | | | | 1040 calls of functionODE | | | | | | 980 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000183089s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.