startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_latest_Buildings.Experimental.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1 -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91 (No OpenGL) (No OpenGL) (No OpenGL), YMD=2022.03.10 10:26 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Warming up {12} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 Buildings.Experimental.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1.bui.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-CORE_ZN-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.Experimental.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1.bui.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.Experimental.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1.bui.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.Experimental.DHC.Loads.BaseClasses.Examples.CouplingSpawnZ1.bui.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0358912s reading init.xml | | | | | | 0.00398313s reading info.xml | | | | | | 0.000299471s [ 0.0%] pre-initialization | | | | | | 1.34984s [ 34.4%] initialization | | | | | | 0.000125055s [ 0.0%] steps | | | | | | 0.0593032s [ 1.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.14099s [ 29.1%] event-handling | | | | | | 0.034361s [ 0.9%] overhead | | | | | | 1.33842s [ 34.1%] simulation | | | | | | 3.92333s [100.0%] total | | | | | events | | | | | | 1007 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 38968 steps taken | | | | | | 55973 calls of functionODE | | | | | | 12008 evaluations of jacobian | | | | | | 1145 error test failures | | | | | | 16 convergence test failures | | | | | | 0.776986s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 3.04sec EnergyPlus Completed Successfully.