startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "EnergyPlus" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Resources/Data/ThermalZones/EnergyPlus/Examples/RefBldgSmallOffice/RefBldgSmallOfficeNew2004_Chicago.dat" EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2022.03.10 12:57 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-ATTIC-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-CORE_ZN-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_1-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_2-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_3-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_4-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.RefBldgSmallOffice.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0133226s reading init.xml | | | | | | 0.00144009s reading info.xml | | | | | | 8.0551e-05s [ 0.0%] pre-initialization | | | | | | 0.989188s [ 48.7%] initialization | | | | | | 7.464e-06s [ 0.0%] steps | | | | | | 0.0276921s [ 1.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.842801s [ 41.5%] event-handling | | | | | | 0.0100216s [ 0.5%] overhead | | | | | | 0.162702s [ 8.0%] simulation | | | | | | 2.03249s [100.0%] total | | | | | events | | | | | | 1007 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 14891 steps taken | | | | | | 14891 calls of functionODE | | | | | | 13883 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0816941s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 1.49sec EnergyPlus Completed Successfully.