startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2022.03.10 12:56 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-LIVING ZONE-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 assert | warning | The following assertion has been violated at time 0.000000 | | | | duc.m_flow >= 0.0 and duc.m_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= duc.m_flow <= 100000.0, has value: -2.63739e-14 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. stdout | info | 3600.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: Calculated Relative Humidity out of range (PsyRhFnTdbWPb) stdout | info | 3600.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: Routine=Unknown, Environment=SPAWN-RUNPERIOD, at Simulation time=01/01 00:50 - 00:50 stdout | info | 3600.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: Dry-Bulb= -8.30 Humidity Ratio= 2.083E-003 Calculated Relative Humidity [%]= 110.02 stdout | info | 3600.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: Relative Humidity being reset to 100.0% LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00708822s reading init.xml | | | | | | 0.000644029s reading info.xml | | | | | | 5.0755e-05s [ 0.0%] pre-initialization | | | | | | 0.820602s [ 92.0%] initialization | | | | | | 2.545e-06s [ 0.0%] steps | | | | | | 0.00329735s [ 0.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.037049s [ 4.2%] event-handling | | | | | | 0.00509189s [ 0.6%] overhead | | | | | | 0.0255869s [ 2.9%] simulation | | | | | | 0.891681s [100.0%] total | | | | | events | | | | | | 143 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2597 steps taken | | | | | | 3053 calls of functionODE | | | | | | 2095 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00575307s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.35sec EnergyPlus Completed Successfully. stdout | info | 85800.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: ** Warning ** Calculated Relative Humidity out of range (PsyRhFnTdbWPb) stdout | info | 85800.000 Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.NoOutputVariable.building: Warning from EnergyPlus: