startTime=0
stopTime=3600
tolerance=1e-06
numberOfIntervals=2500
stepSize=1.44
Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3 -abortSlowSimulation -alarm=480 -lv LOG_STATS
stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3: Using pre-compiled FMU /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 8.1.1-maint.8.1.x/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones3.fmu
stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3: Warning: Variable North_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3/EnergyPlus-simulation-Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3/Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3.fmu. It will not be converted to SI units.
stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3/EnergyPlus-simulation-Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3/Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3.fmu. It will not be converted to SI units.
stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3/EnergyPlus-simulation-Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3/Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3.fmu. It will not be converted to SI units.
stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3: Warning from EnergyPlus: "*** Test warning written by Zones3.core.#10;"
stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3: Warning from EnergyPlus: "*** Test warning written by Zones3.north.#10;"
stdout | info | 0.000 Buildings.ThermalZones.EnergyPlus.BaseClasses.Validation.FMUZoneAdapterZones3: Warning from EnergyPlus: "*** Test warning written by Zones3.south.#10;"
LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_STATS | info | ### STATISTICS ###
| | | | | timer
| | | | | | 0.00173989s reading init.xml
| | | | | | 0.000199865s reading info.xml
| | | | | | 3.8161e-05s [ 0.2%] pre-initialization
| | | | | | 0.0161321s [ 65.3%] initialization
| | | | | | 6.12e-07s [ 0.0%] steps
| | | | | | 0.00111986s [ 4.5%] solver (excl. callbacks)
| | | | | | 0s [ 0.0%] creating output-file
| | | | | | 0.00275888s [ 11.2%] event-handling
| | | | | | 0.00113009s [ 4.6%] overhead
| | | | | | 0.00351848s [ 14.2%] simulation
| | | | | | 0.0246982s [100.0%] total
| | | | | events
| | | | | | 59 state events
| | | | | | 0 time events
| | | | | solver: dassl
| | | | | | 1040 steps taken
| | | | | | 1040 calls of functionODE
| | | | | | 980 evaluations of jacobian
| | | | | | 0 error test failures
| | | | | | 0 convergence test failures
| | | | | | 0.000192933s time of jacobian evaluation
LOG_SUCCESS | info | The simulation finished successfully.