startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_8_Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6 -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2022.03.10 13:03 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-ATTIC-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-CORE_ZN-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_1-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_2-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_3-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_4-RADIANTGAINS", Activity Level Schedule Name values stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". stdout | info | 0.000 Buildings.Experimental.DHC.Loads.Examples.CouplingSpawnZ6.bui.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | info | The following assertion has been violated at time 120.960000 | | | | bui.ports_aHeaWat[1].h_outflow >= -10000000000.0 and bui.ports_aHeaWat[1].h_outflow <= 10000000000.0 assert | info | Variable violating min/max constraint: -10000000000.0 <= bui.ports_aHeaWat[1].h_outflow <= 10000000000.0, has value: -nan assert | info | The following assertion has been violated at time 120.960000 | | | | bui.ports_aChiWat[1].h_outflow >= -10000000000.0 and bui.ports_aChiWat[1].h_outflow <= 10000000000.0 assert | info | Variable violating min/max constraint: -10000000000.0 <= bui.ports_aChiWat[1].h_outflow <= 10000000000.0, has value: -nan assert | debug | division by zero at time 600.000000060111, (a=0) / (b=0), where divisor b expression is: 0.0 Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.58sec EnergyPlus Completed Successfully.