startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./Buildings_8.0.0_Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 8.0.0/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 8.0.0/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgStand-aloneRetailNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 8.0.0/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgMidriseApartmentNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff1.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret1.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff2.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa1.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff3.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | larOff4.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | apa2.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumHea.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumHotWat.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | ret2.pumChi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | warning | The following assertion has been violated at time 50457.600000 | | | | larOff1.heaPum.m2_flow >= 0.0 and larOff1.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff1.heaPum.m2_flow <= 100000.0, has value: -1.81687e-269 assert | warning | The following assertion has been violated at time 50457.600000 | | | | larOff2.heaPum.m2_flow >= 0.0 and larOff2.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff2.heaPum.m2_flow <= 100000.0, has value: -1.81687e-269 assert | warning | The following assertion has been violated at time 50457.600000 | | | | larOff3.heaPum.m2_flow >= 0.0 and larOff3.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff3.heaPum.m2_flow <= 100000.0, has value: -1.81687e-269 assert | warning | The following assertion has been violated at time 50457.600000 | | | | larOff4.heaPum.m2_flow >= 0.0 and larOff4.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff4.heaPum.m2_flow <= 100000.0, has value: -1.81687e-269 assert | warning | The following assertion has been violated at time 63072.000000 | | | | ret1.chi.m1_flow >= 0.0 and ret1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret1.chi.m1_flow <= 100000.0, has value: -6.21032e-171 assert | warning | The following assertion has been violated at time 63072.000000 | | | | ret2.chi.m1_flow >= 0.0 and ret2.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret2.chi.m1_flow <= 100000.0, has value: -6.21032e-171 assert | warning | The following assertion has been violated at time 81993.600000 | | | | ret1.heaPum.m2_flow >= 0.0 and ret1.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret1.heaPum.m2_flow <= 100000.0, has value: -2.24782e-63 assert | warning | The following assertion has been violated at time 81993.600000 | | | | ret2.heaPum.m2_flow >= 0.0 and ret2.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= ret2.heaPum.m2_flow <= 100000.0, has value: -2.24782e-63 assert | warning | The following assertion has been violated at time 151372.800000 | | | | larOff1.chi.m1_flow >= 0.0 and larOff1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff1.chi.m1_flow <= 100000.0, has value: -4.81984e-181 assert | warning | The following assertion has been violated at time 151372.800000 | | | | larOff2.chi.m1_flow >= 0.0 and larOff2.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff2.chi.m1_flow <= 100000.0, has value: -4.81984e-181 assert | warning | The following assertion has been violated at time 151372.800000 | | | | larOff3.chi.m1_flow >= 0.0 and larOff3.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff3.chi.m1_flow <= 100000.0, has value: -4.81984e-181 assert | warning | The following assertion has been violated at time 151372.800000 | | | | larOff4.chi.m1_flow >= 0.0 and larOff4.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= larOff4.chi.m1_flow <= 100000.0, has value: -4.81984e-181 assert | warning | The following assertion has been violated at time 227059.200000 | | | | apa1.heaPum.m2_flow >= 0.0 and apa1.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa1.heaPum.m2_flow <= 100000.0, has value: -9.99764e-25 assert | warning | The following assertion has been violated at time 227059.200000 | | | | apa2.heaPum.m2_flow >= 0.0 and apa2.heaPum.m2_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa2.heaPum.m2_flow <= 100000.0, has value: -9.99764e-25 assert | warning | The following assertion has been violated at time 1217289.600000 | | | | apa1.chi.m1_flow >= 0.0 and apa1.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa1.chi.m1_flow <= 100000.0, has value: -3.76158e-37 assert | warning | The following assertion has been violated at time 1217289.600000 | | | | apa2.chi.m1_flow >= 0.0 and apa2.chi.m1_flow <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= apa2.chi.m1_flow <= 100000.0, has value: -3.76158e-37 assert | warning | The following assertion has been violated at time 4118601.600000 | | | | noEvent(abs(larOff4.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * larOff4.heaPum.eva.vol.steBal.m_flow_small, abs(larOff4.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff4.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 6.0464 W and the mass flow rate equals -1.10219e-06 kg/s, | | | | which results in a temperature difference 395.999 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 7246972.800000 | | | | noEvent(abs(apa2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * apa2.heaPum.eva.vol.steBal.m_flow_small, abs(apa2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.146818 W and the mass flow rate equals -1.95867e-08 kg/s, | | | | which results in a temperature difference 388.576 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 7600176.000000 | | | | noEvent(abs(apa2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * apa2.heaPum.eva.vol.steBal.m_flow_small, abs(apa2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.147611 W and the mass flow rate equals -2.28511e-08 kg/s, | | | | which results in a temperature difference 390.674 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 9303120.000000 | | | | noEvent(abs(larOff4.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * larOff4.heaPum.eva.vol.steBal.m_flow_small, abs(larOff4.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff4.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 4.73414 W and the mass flow rate equals -1.07392e-06 kg/s, | | | | which results in a temperature difference 310.055 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 9561715.200000 | | | | noEvent(abs(ret2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * ret2.heaPum.eva.vol.steBal.m_flow_small, abs(ret2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.ret2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 1.07544 W and the mass flow rate equals -1.67501e-07 kg/s, | | | | which results in a temperature difference 381.882 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 12791001.600000 | | | | noEvent(abs(apa2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * apa2.heaPum.eva.vol.steBal.m_flow_small, abs(apa2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.154325 W and the mass flow rate equals -1.99492e-08 kg/s, | | | | which results in a temperature difference 408.445 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 16039209.600000 | | | | noEvent(abs(larOff4.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * larOff4.heaPum.eva.vol.steBal.m_flow_small, abs(larOff4.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff4.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 5.92408 W and the mass flow rate equals -1.10699e-06 kg/s, | | | | which results in a temperature difference 387.988 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 18158428.800000 | | | | noEvent(abs(ret2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * ret2.heaPum.eva.vol.steBal.m_flow_small, abs(ret2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.ret2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 1.15 W and the mass flow rate equals -1.7218e-07 kg/s, | | | | which results in a temperature difference 408.359 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 20189347.200000 | | | | noEvent(abs(larOff4.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * larOff4.heaPum.eva.vol.steBal.m_flow_small, abs(larOff4.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff4.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 4.76558 W and the mass flow rate equals -1.56693e-06 kg/s, | | | | which results in a temperature difference 312.114 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 23904288.000000 | | | | noEvent(abs(larOff4.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * larOff4.heaPum.eva.vol.steBal.m_flow_small, abs(larOff4.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff4.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 4.55305 W and the mass flow rate equals -1.66592e-06 kg/s, | | | | which results in a temperature difference 298.195 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 25922592.000000 | | | | noEvent(abs(apa2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * apa2.heaPum.eva.vol.steBal.m_flow_small, abs(apa2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.153064 W and the mass flow rate equals -2.61204e-08 kg/s, | | | | which results in a temperature difference 405.106 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 26748835.200000 | | | | noEvent(abs(apa2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * apa2.heaPum.eva.vol.steBal.m_flow_small, abs(apa2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.118112 W and the mass flow rate equals -4.64668e-08 kg/s, | | | | which results in a temperature difference 312.601 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 26931744.000000 | | | | noEvent(abs(ret2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * ret2.heaPum.eva.vol.steBal.m_flow_small, abs(ret2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.ret2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.981694 W and the mass flow rate equals -2.35954e-07 kg/s, | | | | which results in a temperature difference 348.593 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 27896745.600000 | | | | noEvent(abs(apa2.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * apa2.heaPum.eva.vol.steBal.m_flow_small, abs(apa2.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.apa2.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 0.151722 W and the mass flow rate equals -2.16711e-08 kg/s, | | | | which results in a temperature difference 401.556 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. assert | warning | The following assertion has been violated at time 30999888.000000 | | | | noEvent(abs(larOff4.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * larOff4.heaPum.eva.vol.steBal.m_flow_small, abs(larOff4.heaPum.m2_flow))) assert | error | In Buildings.Obsolete.DistrictHeatingCooling.Examples.HeatingCoolingHotWater3ClustersBaseCase.larOff4.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 3.07928 W and the mass flow rate equals -2.32292e-06 kg/s, | | | | which results in a temperature difference 201.673 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false. stdout | warning | Integrator attempt to handle a problem with a called assert. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.23795s reading init.xml | | | | | | 0.0237717s reading info.xml | | | | | | 0.00130502s [ 0.0%] pre-initialization | | | | | | 0.0295984s [ 0.7%] initialization | | | | | | 0.000885912s [ 0.0%] steps | | | | | | 0.0792483s [ 1.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0154804s [ 0.3%] event-handling | | | | | | 0.128275s [ 2.8%] overhead | | | | | | 4.2508s [ 94.3%] simulation | | | | | | 4.50559s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 663 steps taken | | | | | | 1053 calls of functionODE | | | | | | 134 evaluations of jacobian | | | | | | 62 error test failures | | | | | | 0 convergence test failures | | | | | | 0.228926s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.