startTime=0 stopTime=315710 tolerance=1e-06 numberOfIntervals=2500 stepSize=126.284 Regular simulation: ./Buildings_7.0.0_Buildings.Utilities.Plotters.Examples.ControlsVerification_CoolingCoilValve -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "OA_Temp" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 7.0.1/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/OA_Temp.mos" stdout | info | ... loading "SA_Clg_Stpt" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 7.0.1/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/SA_Clg_Stpt.mos" stdout | info | ... loading "Clg_Coil_Valve" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 7.0.1/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/Clg_Coil_Valve.mos" stdout | info | ... loading "VFD_Fan_Feedback" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 7.0.1/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/VFD_Fan_Feedback.mos" stdout | info | ... loading "VFD_Fan_Enable" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 7.0.1/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/VFD_Fan_Enable.mos" stdout | info | ... loading "Supply_Air_Temp" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 7.0.1/Resources/Data/Utilities/Plotters/Examples/ControlsVerification_CoolingCoilValve/Supply_Air_Temp.mos" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00789408s reading init.xml | | | | | | 0.000820138s reading info.xml | | | | | | 9.2093e-05s [ 0.0%] pre-initialization | | | | | | 0.185503s [ 2.2%] initialization | | | | | | 8.2024e-05s [ 0.0%] steps | | | | | | 1.21395s [ 14.7%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 2.4776s [ 30.0%] event-handling | | | | | | 0.122415s [ 1.5%] overhead | | | | | | 4.2503s [ 51.5%] simulation | | | | | | 8.24995s [100.0%] total | | | | | events | | | | | | 63144 state events | | | | | | 63143 time events | | | | | solver: dassl | | | | | | 802940 steps taken | | | | | | 899588 calls of functionODE | | | | | | 734501 evaluations of jacobian | | | | | | 21450 error test failures | | | | | | 0 convergence test failures | | | | | | 0.907183s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. stdout | info | Wrote plot file "coolingCoilValve_validationPlots.html".