startTime=1.5552e+07 stopTime=1.56384e+07 tolerance=1e-07 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_7.0.0_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC -abortSlowSimulation -alarm=480 -lv LOG_STATS stdout | info | ... loading "tab1" from "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Buildings 7.0.1/Resources/weatherdata/USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.mos" assert | warning | The following assertion has been violated during initialization at time 15552000.000000 | | | | hvaCon2.fan.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 15552000.000000 | | | | hvaCon2.fan2.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | warning | The following assertion has been violated at time 15552051.840000 | | | | hvaCon2.fan2.filter.y >= 0.0 and hvaCon2.fan2.filter.y <= 100000.0 assert | warning | Variable violating min/max constraint: 0.0 <= hvaCon2.fan2.filter.y <= 100000.0, has value: -2.00036e-21 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.260464s reading init.xml | | | | | | 0.0195046s reading info.xml | | | | | | 0.000350728s [ 0.0%] pre-initialization | | | | | | 0.0599692s [ 1.2%] initialization | | | | | | 0.000175399s [ 0.0%] steps | | | | | | 0.456771s [ 9.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.18482s [ 24.3%] event-handling | | | | | | 0.0662513s [ 1.4%] overhead | | | | | | 3.10344s [ 63.7%] simulation | | | | | | 4.87178s [100.0%] total | | | | | events | | | | | | 257 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 21601 steps taken | | | | | | 27493 calls of functionODE | | | | | | 3959 evaluations of jacobian | | | | | | 512 error test failures | | | | | | 0 convergence test failures | | | | | | 1.7141s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.