startTime=0 stopTime=5000 tolerance=1e-06 numberOfIntervals=2500 stepSize=2 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatExchangers.ActiveBeams.Validation.NumberOfBeams -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0379327s reading init.xml | | | | | | 0.00417204s reading info.xml | | | | | | 0.000199264s [ 0.8%] pre-initialization | | | | | | 0.000390934s [ 1.5%] initialization | | | | | | 2.544e-06s [ 0.0%] steps | | | | | | 6.069e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00055307s [ 2.1%] event-handling | | | | | | 0.00793444s [ 30.6%] overhead | | | | | | 0.0168301s [ 64.9%] simulation | | | | | | 0.0259165s [100.0%] total | | | | | events | | | | | | 3 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 12509 steps taken | | | | | | 12509 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.