Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week.conf.json loadFile("/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week") translateModel(BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.6871/0.6871, allocations: 131 MB / 146.3 MB, free: 1.305 MB / 106.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0008752/0.0008753, allocations: 184.2 kB / 176.4 MB, free: 4.895 MB / 138.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.311/1.311, allocations: 225.7 MB / 431.9 MB, free: 8.75 MB / 314.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008365/0.0008364, allocations: 97.31 kB / 0.5003 GB, free: 9.824 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0002939/0.0002939, allocations: 12 kB / 0.5886 GB, free: 72.62 MB / 426.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1134/0.1137, allocations: 79.6 MB / 0.6663 GB, free: 8.863 MB / 442.7 MB Notification: Performance of NFInst.instantiate(BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week): time 0.003257/0.117, allocations: 2.479 MB / 0.6687 GB, free: 6.371 MB / 442.7 MB Notification: Performance of NFInst.instExpressions: time 0.008915/0.1259, allocations: 8.049 MB / 0.6766 GB, free: 13.58 MB / 458.7 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0002455/0.1262, allocations: 11.88 kB / 0.6766 GB, free: 13.57 MB / 458.7 MB Notification: Performance of NFTyping.typeComponents: time 0.001681/0.1279, allocations: 0.7677 MB / 0.6773 GB, free: 12.8 MB / 458.7 MB Notification: Performance of NFTyping.typeBindings: time 0.0007997/0.1287, allocations: 211 kB / 0.6775 GB, free: 12.59 MB / 458.7 MB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/BuildSysPro 3.5.0/IBPSA/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/aggregationWeightingFactors.mo:14:32-14:44:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/converted-libraries/.openmodelica/libraries/BuildSysPro 3.5.0/IBPSA/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/aggregationWeightingFactors.mo:14:3-14:81:writable] Error: Non-array modification ‘"K/J"‘ for array component ‘unit‘, possibly due to missing ‘each‘. Notification: Performance of FrontEnd: time 0.0006768/0.1294, allocations: 236.9 kB / 0.6778 GB, free: 12.36 MB / 458.7 MB