Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=4e+06 tolerance=1e-06 numberOfIntervals=4444 stepSize=900.09 Regular simulation: ./TransiEnt_TransiEnt.Storage.Electrical.Check.TestSuperCapacitor -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/REProfiles/Wind2012_TenneT_900s.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityDemandHH_900s_01.01.20120-01.01.20130.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. DASKR-- AT T (=R1) AND STEPSIZE H (=R2) THE In above, R1 = 1.0027590223851E+04 R2 = 7.5385998472110E-12 DASKR-- ERROR TEST FAILED REPEATEDLY OR WITH ABS(H)=HMIN LOG_STDOUT | warning | DDASSL had repeated error test failures on the last attempted step. LOG_STDOUT | warning | can't continue. time = 10027.590224 LOG_STDOUT | info | model terminate | Integrator failed. | Simulation terminated at time 10027.6 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 5.0876e-05s [ 0.1%] pre-initialization | | | | | | 0.0355708s [ 97.2%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000183068s [ 0.5%] solver (excl. callbacks) | | | | | | 2.034e-06s [ 0.0%] creating output-file | | | | | | 0.00014834s [ 0.4%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00062524s [ 1.7%] simulation | | | | | | 0.0365803s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 1 time events | | | | | solver: dassl | | | | | | 290 steps taken | | | | | | 540 calls of functionODE | | | | | | 326 evaluations of jacobian | | | | | | 80 error test failures | | | | | | 7 convergence test failures | | | | | | 0.000137861s time of jacobian evaluation