Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=36000 tolerance=1e-06 numberOfIntervals=2500 stepSize=14.4 Regular simulation: ./TransiEnt_TransiEnt.Storage.Base.Check.TestGenericStorageHyst -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 5.1026e-05s [ 0.1%] pre-initialization | | | | | | 0.0263739s [ 41.1%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00644251s [ 10.1%] solver (excl. callbacks) | | | | | | 1.934e-06s [ 0.0%] creating output-file | | | | | | 0.0169389s [ 26.4%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0142904s [ 22.3%] simulation | | | | | | 0.0640986s [100.0%] total | | | | | events | | | | | | 918 state events | | | | | | 4 time events | | | | | solver: dassl | | | | | | 6485 steps taken | | | | | | 6664 calls of functionODE | | | | | | 5525 evaluations of jacobian | | | | | | 34 error test failures | | | | | | 33 convergence test failures | | | | | | 0.00252467s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.