Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation: ./TransiEnt_TransiEnt.Grid.Heat.HeatGridControl.Check.Test_DHG_FeedForward_Controller -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/\heat\TypicalHeatLoadDay_AbsoluteValues_MonoIncreasing.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/\heat\TypicalHeatLoadDay_AbsoluteValues_MonoIncreasing.txt LOG_ASSERT | debug | Not possible to open file "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/\heat\TypicalHeatLoadDay_AbsoluteValues_MonoIncreasing.txt": No such file or directory LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Types.mo:105:5-136:20:writable] | | | | The constructor of external object Modelica.Blocks.Types.ExternalCombiTimeTable failed. LOG_ASSERT | info | simulation terminated by an assertion at initialization LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.9917e-05s [ 0.6%] pre-initialization | | | | | | 0s [ 0.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0s [ 0.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00522152s [ 99.4%] simulation | | | | | | 0.00525143s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: | | | | | | 0 steps taken | | | | | | 0 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation