Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=2500 stepSize=4 Regular simulation: ./TransiEnt_TransiEnt.Consumer.Systems.FridgePoolControl.Check.TestPoolResponsePrequalification -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.7429e-05s [ 0.0%] pre-initialization | | | | | | 0.0357761s [ 4.3%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.559535s [ 67.0%] solver (excl. callbacks) | | | | | | 3.657e-06s [ 0.0%] creating output-file | | | | | | 0.143603s [ 17.2%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0963595s [ 11.5%] simulation | | | | | | 0.835324s [100.0%] total | | | | | events | | | | | | 341 state events | | | | | | 104 time events | | | | | solver: dassl | | | | | | 5863 steps taken | | | | | | 5865 calls of functionODE | | | | | | 5372 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.030736s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.