Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=96 stepSize=900 Regular simulation: ./TransiEnt_TransiEnt.Components.Gas.Engines.Check.Test_Engine_idealGas -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | warning | The nominal value of simCenter.rh_amb is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/heat/HeatingCurve_LHN_EonHanse.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | debug | division by zero at time 900, (a=0) / (b=0), where divisor b expression is: sink.gasPort.m_flow LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Basics/Interfaces/Gas/IdealGasEnthPort.mo:45:3-45:153:writable] | | | | The following assertion has been violated at time 900.000000 | | | | ((engine.gasPortOut.xi_outflow[1] >= 0.0 and engine.gasPortOut.xi_outflow[1] <= 1.0), engine.gasPortOut.xi_outflow[1]=-nan) --> "Variable violating min/max constraint: 0.0 <= engine.gasPortOut.xi_outflow[1] <= 1.0, has value: -nan" LOG_ASSERT | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: sink.gasPort.m_flow LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.9565e-05s [ 0.1%] pre-initialization | | | | | | 0.0284637s [ 93.7%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.000229574s [ 0.8%] solver (excl. callbacks) | | | | | | 3.075e-06s [ 0.0%] creating output-file | | | | | | 4.791e-05s [ 0.2%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.00160645s [ 5.3%] simulation | | | | | | 0.0303902s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 0 steps taken | | | | | | 0 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000496065s time of jacobian evaluation