Environment - simulationEnvironment: startTime=0 stopTime=2000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.8 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankHeating -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 0.800000 | | | | ((flowResistance1.inlet.m_flow > tank.m_flow_assert)) --> "In "TankHeating.tank": Negative massflow at tank inlet" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 1.9357e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.000187122s [ 0.1%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00684298s [ 2.7%] solver (excl. callbacks) LOG_STATS | info | | 0.00211733s [ 0.8%] creating output-file LOG_STATS | info | | 0.0716951s [ 28.6%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.170154s [ 67.8%] simulation LOG_STATS | info | | 0.251016s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 4 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 2598 steps taken LOG_STATS | info | | 3977 calls of functionODE LOG_STATS | info | | 392 evaluations of jacobian LOG_STATS | info | | 197 error test failures LOG_STATS | info | | 7 convergence test failures LOG_STATS | info | | 0.071193s time of jacobian evaluation