Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.02 Regular simulation: ./ThermofluidStream_ThermofluidStream.Undirected.FlowControl.Tests.BasicControlValve -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((valveLinear.u_in <= 1.0 and valveLinear.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((valveLinear.u_in <= 1.0 and valveLinear.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Undirected/FlowControl/Internal/PartialValve.mo:33:3-33:108:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((valveLinear.u_in <= 1.0 and valveLinear.u_in >= 0.0)) --> "Actuator signal out of valid range [0,1]" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.4716e-05s [ 0.2%] pre-initialization LOG_STATS | info | | 0.00012725s [ 1.2%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00116068s [ 11.1%] solver (excl. callbacks) LOG_STATS | info | | 0.000847979s [ 8.1%] creating output-file LOG_STATS | info | | 0.00100019s [ 9.5%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.00731583s [ 69.8%] simulation LOG_STATS | info | | 0.0104767s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 19 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 2373 steps taken LOG_STATS | info | | 3197 calls of functionODE LOG_STATS | info | | 552 evaluations of jacobian LOG_STATS | info | | 92 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.000563117s time of jacobian evaluation