Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation: ./ThermofluidStream_ThermofluidStream.Idealized.Tests.Processes.Isochoric.Warnings2 -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/Isochoric.mo:117:5-117:280:writable] | | | | The following assertion has been violated at time 0.260000 | | | | ((noEvent(abs(dT2c.Q_flow) < 2.220446049250313e-16) or noEvent(abs(dT2c.du) > 2.220446049250313e-16))) --> "The heat flow rate in Warnings2.dT2c is non zero, but the difference in specific internal energy is zero, implying that the mass flow rate m_flow := Q_flow/du is infinite. | | | | The result is regularized." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/Isochoric.mo:117:5-117:280:writable] | | | | The following assertion has been violated at time 0.260000 | | | | ((noEvent(abs(dT2c.Q_flow) < 2.220446049250313e-16) or noEvent(abs(T_out2c.du) > 2.220446049250313e-16))) --> "The heat flow rate in Warnings2.T_out2c is non zero, but the difference in specific internal energy is zero, implying that the mass flow rate m_flow := Q_flow/du is infinite. | | | | The result is regularized." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/Isochoric.mo:117:5-117:280:writable] | | | | The following assertion has been violated at time 0.260000 | | | | ((noEvent(abs(dT2c.Q_flow) < 2.220446049250313e-16) or noEvent(abs(dT2.du) > 2.220446049250313e-16))) --> "The heat flow rate in Warnings2.dT2 is non zero, but the difference in specific internal energy is zero, implying that the mass flow rate m_flow := Q_flow/du is infinite. | | | | The result is regularized." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Idealized/Processes/Isochoric.mo:117:5-117:280:writable] | | | | The following assertion has been violated at time 0.260000 | | | | ((noEvent(abs(dT2c.Q_flow) < 2.220446049250313e-16) or noEvent(abs(T_out2.du) > 2.220446049250313e-16))) --> "The heat flow rate in Warnings2.T_out2 is non zero, but the difference in specific internal energy is zero, implying that the mass flow rate m_flow := Q_flow/du is infinite. | | | | The result is regularized." LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.5278e-05s [ 2.2%] pre-initialization LOG_STATS | info | | 0.0001062s [ 9.3%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0s [ 0.0%] solver (excl. callbacks) LOG_STATS | info | | 4.7238e-05s [ 4.1%] creating output-file LOG_STATS | info | | 0s [ 0.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.000965468s [ 84.4%] simulation LOG_STATS | info | | 0.00114418s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 8 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: euler LOG_STATS | info | | 108 steps taken LOG_STATS | info | | 108 calls of functionODE LOG_STATS | info | | 0 evaluations of jacobian LOG_STATS | info | | 0 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0s time of jacobian evaluation