Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=100 stepSize=0.01 Regular simulation: ./ThermofluidStream_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step5Sink_free -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((massFlowRate.p_min >= 611.657 and massFlowRate.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= massFlowRate.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((superheater.p_min >= 611.657 and superheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= superheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((preheater.p_min >= 611.657 and preheater.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= preheater.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((boiler.p_min >= 611.657 and boiler.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= boiler.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/Interfaces/SISOFlow.mo:27:3-28:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump.p_min >= 611.657 and pump.p_min <= 1e8)) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.1891e-05s [ 0.2%] pre-initialization LOG_STATS | info | | 0.000483761s [ 4.1%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0s [ 0.0%] solver (excl. callbacks) LOG_STATS | info | | 0.000103556s [ 0.9%] creating output-file LOG_STATS | info | | 0s [ 0.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.0110492s [ 94.8%] simulation LOG_STATS | info | | 0.0116584s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 1 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: euler LOG_STATS | info | | 101 steps taken LOG_STATS | info | | 101 calls of functionODE LOG_STATS | info | | 0 evaluations of jacobian LOG_STATS | info | | 0 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0s time of jacobian evaluation