Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.02 Regular simulation: ./ThermofluidStream_ThermofluidStream.FlowControl.Tests.BasicControlValve -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((valveLinear.u_in <= 1.0 and valveLinear.u_in >= 0.0)) --> "In "BasicControlValve.valveEqualPercentage": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((valveLinear.u_in <= 1.0 and valveLinear.u_in >= 0.0)) --> "In "BasicControlValve.valveParabolic": Actuator signal out of valid range [0,1]" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.0/FlowControl/Internal/PartialValve.mo:33:3-33:137:writable] | | | | The following assertion has been violated at time 15.000000 | | | | ((valveLinear.u_in <= 1.0 and valveLinear.u_in >= 0.0)) --> "In "BasicControlValve.valveLinear": Actuator signal out of valid range [0,1]" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.2502e-05s [ 0.7%] pre-initialization LOG_STATS | info | | 0.000102293s [ 3.2%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.000205929s [ 6.4%] solver (excl. callbacks) LOG_STATS | info | | 0.000395642s [ 12.4%] creating output-file LOG_STATS | info | | 0.000289448s [ 9.1%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.002177s [ 68.2%] simulation LOG_STATS | info | | 0.00319281s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 2 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 178 steps taken LOG_STATS | info | | 306 calls of functionODE LOG_STATS | info | | 73 evaluations of jacobian LOG_STATS | info | | 9 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 5.3158e-05s time of jacobian evaluation