Environment - simulationEnvironment: startTime=0 stopTime=600 tolerance=1e-06 numberOfIntervals=600 stepSize=1 Regular simulation: ./ThermoSysPro_ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicReliefValve -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.2622e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.0011159s [ 0.1%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.000500236s [ 0.0%] solver (excl. callbacks) LOG_STATS | info | | 0.000306691s [ 0.0%] creating output-file LOG_STATS | info | | 0.393098s [ 39.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.612111s [ 60.8%] simulation LOG_STATS | info | | 1.00715s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 10 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 590 steps taken LOG_STATS | info | | 895 calls of functionODE LOG_STATS | info | | 181 evaluations of jacobian LOG_STATS | info | | 37 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.0821083s time of jacobian evaluation