Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | debug | Division by zero bpro.R / p in function context LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 1.9066e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.00546029s [ 1.9%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00039492s [ 0.1%] solver (excl. callbacks) LOG_STATS | info | | 0.00465785s [ 1.6%] creating output-file LOG_STATS | info | | 0.0947397s [ 33.2%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.179889s [ 63.1%] simulation LOG_STATS | info | | 0.285161s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 0 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 22 steps taken LOG_STATS | info | | 22 calls of functionODE LOG_STATS | info | | 21 evaluations of jacobian LOG_STATS | info | | 0 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.0492044s time of jacobian evaluation