Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermalSeparation_ThermalSeparation.Examples.Testing.Complex.CycleComplex.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.0008227/0.0008227, allocations: 92.2 kB / 20.94 MB, free: 3.609 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.0009186/0.0009186, allocations: 169 kB / 24.25 MB, free: 308 kB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.021/1.021, allocations: 177.1 MB / 204.6 MB, free: 5.234 MB / 186.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo): time 0.4287/0.4287, allocations: 50.76 MB / 311.8 MB, free: 5.043 MB / 282.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:146:3-158:16:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/Compressor.mo:160:3-168:15:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:145:4-157:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:159:5-167:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:320:4-332:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Compressors/OldCompressorModels.mo:334:5-342:17:writable] Warning: External function annotation should occur on the external-clause, not on the function. " [Timeout remaining time 179] Using package ThermalSeparation with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(ThermalSeparation.Examples.Testing.Complex.CycleComplex,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermalSeparation_ThermalSeparation.Examples.Testing.Complex.CycleComplex") translateModel(ThermalSeparation.Examples.Testing.Complex.CycleComplex,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermalSeparation_ThermalSeparation.Examples.Testing.Complex.CycleComplex") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 2.685e-06/2.685e-06, allocations: 0 / 395.8 MB, free: 1.312 MB / 362.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 3.204e-05/3.473e-05, allocations: 2.312 kB / 395.8 MB, free: 1.309 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Media/IdealGasMixtures/BaseClasses/BaseIdealGasMixture.mo:32:3-34:73:writable] Error: BaseIdealGasMixture is partial, name lookup is not allowed in partial classes. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermalSeparation master/Components/Columns/BaseClasses/BaseColumn.mo:75:2-75:113:writable] Error: Class MediumVapour.BaseProperties not found in scope BaseColumn. Notification: Performance of FrontEnd: time 0.347/0.347, allocations: 129.5 MB / 0.513 GB, free: 11.15 MB / 410.7 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.4405033700168133]