Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./IDEAS_IDEAS.Fluid.HeatPumps.Examples.HeatPump_WaterWaterTSet -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 4.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWaterTSet.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 4.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in HeatPump_WaterWaterTSet.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.9065e-05s [ 0.2%] pre-initialization LOG_STATS | info | | 0.000314773s [ 2.6%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.000908944s [ 7.6%] solver (excl. callbacks) LOG_STATS | info | | 0.00185211s [ 15.5%] creating output-file LOG_STATS | info | | 0.00217133s [ 18.2%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.00666233s [ 55.8%] simulation LOG_STATS | info | | 0.0119385s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 13 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 838 steps taken LOG_STATS | info | | 1031 calls of functionODE LOG_STATS | info | | 212 evaluations of jacobian LOG_STATS | info | | 13 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.000207675s time of jacobian evaluation