Dynawo_dev test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
81 81 81 81 81 81 78 69

Test started: 2026-11-02 14:19:42
Total time taken: 0:52:09
System info: ryzen-9950x: AMD Ryzen 9 9950X3D 16-Core Processor, 124 GB RAM, Ubuntu 26.04.1 LTS

OpenModelica Version: v1.28.0-dev.1682+g1afe61aa11.cmake
OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
1fccde72026-11-02 13:57:35 +0100Martin SjölundBuildSysPro: do not force headers into every source (#385)

Tested Library: Dynawo_dev 2.0.0

{
 "path": "dynawo/sources/Models/Modelica/Dynawo",
 "sha": "b1d50a690a9e5b3a76210b353a7cfd0aa495e664",
 "support": "noSupport",
 "uses": {
  "Modelica": "3.2.3"
 },
 "version": "2.0.0-master",
 "wasm": {
  "2": {
   "generation": 1,
   "sha256": "abfbc4c7a83c7af72886aaa5d6f45e8ba409aa42ebc1baaf61a508a7514eb350",
   "systemLibraries": [
    "libc"
   ],
   "zipfile": "https://libraries.openmodelica.org/precompiled/wasm32-wasip1/omc-1/Dynawo-wasm32-wasip1-4eb0d74d63821cf7.zip"
  }
 },
 "zipfile": "https://github.com/dynawo/dynawo/archive/b1d50a690a9e5b3a76210b353a7cfd0aa495e664.zip"
}

BuildModel time limit: 660s
Simulation time limit: 240s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default

Reference Files: https://github.com/dynawo/dynawo (b1d50a690a9e5b3a76210b353a7cfd0aa495e664)

CommitDateAuthorSummary
b1d50a690a92026-10-28 09:24:42 +0100Joy El Feghali#4223 Add missing switchOffSignal in OM example

Verified using: v1.28.0-dev.1665+gdf4cfba.cmake (diffSimulationResults)

Flags:
setCommandLineOptions("--simCodeTarget=C+Rust")
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
setCommandLineOptions("--allowNonStandardModelica=implicitParameterStartAttribute,illegalConditionalContext");
Config:
{
 "extraCustomCommands": [
  "setCommandLineOptions(\"--allowNonStandardModelica=implicitParameterStartAttribute,illegalConditionalContext\");"
 ],
 "library": "Dynawo",
 "libraryVersion": "master",
 "libraryVersionNameForTests": "dev",
 "referenceFileExtension": "csv",
 "referenceFileNameDelimiter": ".",
 "referenceFiles": {
  "destination": "ReferenceFiles/Dynawo",
  "git-directory": "dynawo/sources/Models/Modelica/Dynawo/Examples/references",
  "giturl": "https://github.com/dynawo/dynawo"
 },
 "referenceFinalDot": "_res."
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
Dynawo.Examples.BESS.WECC.BESSCurrentSource (sim)0.06 (6 verified)0.192.441.930.050.110.030.232.015.36
Dynawo.Examples.BESS.WECC.BESSCurrentSourceExternalPCS (sim)0.08 (6 verified)0.172.451.800.090.100.020.222.025.30
Dynawo.Examples.BESS.WECC.BESSCurrentSourceNoPPC (sim)0.05 (6 verified)0.101.761.800.050.080.020.051.564.38
Dynawo.Examples.ENTSOE.TestCase1 (sim)0.02 (4 verified)0.082.001.720.070.060.010.061.794.59
Dynawo.Examples.ENTSOE.TestCase2 (sim)0.01 (4 verified)0.041.811.680.030.050.010.051.664.25
Dynawo.Examples.ENTSOE.TestCase3 (sim)0.01 (4 verified)0.142.541.570.040.080.020.232.184.99
Dynawo.Examples.GridCodeSimulations.RunSimulations (sim)0.03 (15 verified)0.8315.871.720.772.390.291.0911.3319.15
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI2Xcca (sim)0.49 (7 verified)0.173.011.530.080.120.030.222.565.95
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI2Xccb (sim)0.49 (7 verified)0.173.051.540.080.120.020.222.626.01
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI5 (sim)0.60 (7 verified)0.453.121.460.060.120.170.072.706.39
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI6 (sim)0.43 (7 verified)0.172.991.570.060.120.030.252.525.90
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI7QMax (sim)0.52 (7 verified)0.182.971.670.070.110.030.242.526.05
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI7QMin (sim)0.60 (7 verified)0.153.001.610.070.110.030.252.546.06
Dynawo.Examples.GridCodeSimulations.SheetSimulations.SheetI10 (sim)3.40 (8 verified)1.053.261.720.130.140.200.082.7110.30
Dynawo.Examples.GridForming.EpriSmib (sim)0.01 (4 verified)0.031.811.620.040.070.010.051.644.15
Dynawo.Examples.GridForming.GridForming (sim)0.02 (10 verified)1.303.071.660.040.330.020.072.616.73
Dynawo.Examples.HVDC.HVDC (sim)0.36 (3/9 failed)1.152.851.630.090.100.020.222.417.02
Dynawo.Examples.IEEE14.TestCases.IEEE14CLA (sim)0.01 (18 verified)0.063.491.580.050.160.180.122.985.78
Dynawo.Examples.IEEE14.TestCases.IEEE14DisconnectLine (sim)0.01 (18 verified)0.023.391.590.070.190.020.292.815.63
Dynawo.Examples.IEEE14.TestCases.IEEE14NoEvent (sim)0.01 (18 verified)0.033.241.590.050.140.020.272.775.58
Dynawo.Examples.IEEE57.TestCases.IEEE57DisconnectLine (sim)0.01 (3 verified)0.1010.611.530.221.040.050.898.4212.89
Dynawo.Examples.IEEE57.TestCases.IEEE57HvdcPsDisconnectLine (sim)0.01 (4 verified)0.1311.091.620.281.400.100.828.4913.54
Dynawo.Examples.IEEE57.TestCases.IEEE57NoEvent (sim)0.01 (18 verified)0.109.981.640.231.050.050.847.8112.48
Dynawo.Examples.IEEE118.TestCases.IEEE118NoEvent (sim)0.01 (13 verified)0.7937.091.561.504.330.582.4728.2140.21
Dynawo.Examples.IllustrativeExamples.DynaFlow.CoordinatedVControl (sim)0.01 (7 verified)0.021.541.500.040.040.010.041.423.79
Dynawo.Examples.IllustrativeExamples.DynaFlow.PhaseShifterTransformer (sim)0.01 (6 verified)0.011.301.660.020.030.000.031.223.66
Dynawo.Examples.InertialGrid.DoubleInertialGrid (sim)0.08 (2 verified)0.371.491.690.020.050.010.041.384.33
Dynawo.Examples.LoadFrequencyDependent.LoadAlphaBetaFrequencyDependent (sim)0.01 (2/3 failed)0.011.291.610.010.030.010.021.223.66
Dynawo.Examples.LoadFrequencyDependent.LoadZIPFrequencyDependent (sim)0.01 (3 verified)0.031.241.520.010.030.010.021.163.43
Dynawo.Examples.Nordic.TestCases.LoadFlow (sim)0.01 (7 verified)0.0711.931.540.291.840.260.628.9214.23
Dynawo.Examples.Nordic.TestCases.TestCase (sim)0.05 (5/6 failed)35.5560.071.542.544.800.424.7247.5998.16
Dynawo.Examples.Photovoltaics.WECC.PVCurrentSource (sim)0.04 (4 verified)0.112.401.610.070.100.020.281.924.91
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSource2 (sim)0.05 (4 verified)0.132.501.670.080.130.030.281.975.08
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSource4 (sim)0.49 (4 verified)0.162.611.640.100.140.030.252.095.64
Dynawo.Examples.Photovoltaics.WECC.PVVoltageSourceNoPPC (sim)0.34 (4 verified)0.131.911.690.050.080.020.061.704.82
Dynawo.Examples.RVS.TestCases.LoadFlow (sim)0.02 (4/7 failed)5.0011.331.600.231.500.100.858.6518.66
Dynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadNoRestorative (sim)0.04 (2 verified)69.96244.781.674.189.151.4626.28203.70317.34
Dynawo.Examples.RVS.TestCases.TestA.TestAAlphaBetaLoadRestorative (sim)0.03 (2 verified)74.59249.961.663.999.992.1526.09207.75327.15
Dynawo.Examples.RVS.TestCases.TestA.TestAShuntNoRestorative (sim)0.04 (1/7 failed)35.35244.081.674.469.401.5326.47202.23282.43
Dynawo.Examples.RVS.TestCases.TestB.TestBNoSvcLoadReset (sim)0.06 (7 verified)108.89248.871.564.169.692.3026.17206.55360.24
Dynawo.Examples.RVS.TestCases.TestB.TestBNoSvcNoLoadReset (sim)0.05 (7 verified)151.49247.891.554.378.831.6227.66205.41401.91
Dynawo.Examples.RVS.TestCases.TestB.TestBSvcLoadReset (sim)0.04 (7 verified)74.73250.431.614.239.692.1826.87207.46327.64
Dynawo.Examples.RVS.TestCases.TestB.TestBSvcNoLoadReset (sim)0.06 (7 verified)81.43248.331.604.489.191.6627.38205.62332.30
Dynawo.Examples.SMIB.SMIBStepEfdPm (sim)0.01 (3 verified)0.021.671.480.020.040.010.051.553.85
Dynawo.Examples.SMIB.SMIBStepPm (sim)0.01 (3 verified)0.061.621.570.020.050.010.041.493.91
Dynawo.Examples.SMIB.Standard.GovCt2St4b (sim)0.02 (5 verified)0.052.681.550.040.090.020.222.324.95
Dynawo.Examples.SMIB.Standard.GovHydro4St4b (sim)0.01 (4 verified)0.072.071.590.030.060.020.061.904.40
Dynawo.Examples.SMIB.Standard.GovSteam1St4b2 (sim)0.01 (5 verified)0.062.201.560.040.070.020.072.014.48
Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b1 (sim)0.01 (5 verified)0.052.421.590.050.090.020.262.004.82
Dynawo.Examples.SMIB.Standard.GovSteam1St4bPss2b3 (sim)0.01 (5 verified)0.182.851.530.050.090.020.242.445.20
Dynawo.Examples.SMIB.Standard.GovSteamEuSt4b (sim)0.02 (5 verified)0.052.561.520.030.090.020.212.214.78
Dynawo.Examples.SVarC.SVarCFaultImp (sim)0.00 (3 verified)0.011.111.510.020.020.000.031.043.29
Dynawo.Examples.SVarC.SVarCLoadVarQ (sim)0.01 (3 verified)0.011.291.550.020.030.000.031.213.53
Dynawo.Examples.SVarC.SVarCLoadVarQLarge (sim)0.01 (3 verified)0.011.281.470.020.020.000.031.213.36
Dynawo.Examples.SVarC.SVarCModeChange (sim)0.01 (3 verified)0.011.141.680.020.020.000.031.073.53
Dynawo.Examples.SVarC.SVarCStepURef (sim)0.01 (2 verified)0.011.141.660.020.030.000.031.063.50
Dynawo.Examples.SystemFrequencyResponse.ReducedOrderSFR (sim)0.01 (2 verified)0.010.961.630.010.010.000.010.933.27
Dynawo.Examples.SystemFrequencyResponse.SimplifiedSFR (sim)0.01 (2 verified)0.021.061.610.010.010.000.021.023.32
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2015 (sim)0.06 (3/4 failed)0.416.111.620.150.490.040.494.949.01
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020 (sim) 0.166.931.650.200.600.050.725.359.41
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020FOCB (sim)0.23 (2/4 failed)2.066.391.630.180.530.050.754.8911.33
Dynawo.Examples.Wind.IEC.Neplan.WPP4ACurrentSource2020UDip (sim) 165.446.571.570.200.590.080.754.95174.26
Dynawo.Examples.Wind.IEC.Neplan.WPP4BCurrentSource2020 (sim)0.41 (3/4 failed)2.656.971.690.230.620.080.725.3112.87
Dynawo.Examples.Wind.IEC.Neplan.WPP4BCurrentSource2020FOCB (sim)0.19 (3/4 failed)1.596.651.620.200.560.070.725.1111.07
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015 (sim)0.04 (3 verified)0.274.451.600.100.400.030.383.547.08
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2015FOCB (sim)0.03 (3 verified)0.194.471.560.100.400.030.373.576.93
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2020 (sim)0.04 (4 verified)0.284.601.610.090.400.040.383.697.21
Dynawo.Examples.Wind.IEC.Neplan.WT4ACurrentSource2020FOCB (sim)0.03 (4 verified)0.204.571.500.090.350.030.363.757.00
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2015 (sim)0.04 (3 verified)0.274.601.580.150.560.030.393.487.15
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2015FOCB (sim)0.04 (3 verified)0.204.441.560.090.390.030.353.586.90
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020 (sim) 0.204.771.560.110.490.030.363.777.14
Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020FOCB (sim)0.03 (4 verified)0.234.691.540.110.340.030.343.887.17
Dynawo.Examples.Wind.WECC.WT3CurrentSource1 (sim)0.37 (4 verified)0.212.161.470.040.080.020.221.804.90
Dynawo.Examples.Wind.WECC.WT3CurrentSource2 (sim)0.36 (4 verified)0.142.331.550.060.160.020.231.865.04
Dynawo.Examples.Wind.WECC.WT4ACurrentSource (sim)0.35 (4 verified)0.131.761.560.040.060.010.051.604.47
Dynawo.Examples.Wind.WECC.WT4BCurrentSource (sim)0.27 (4 verified)0.141.631.500.030.060.010.061.464.30
Dynawo.Examples.Wind.WECC.WTG3CurrentSource1 (sim)0.44 (4 verified)0.172.671.530.060.100.020.202.285.61
Dynawo.Examples.Wind.WECC.WTG3CurrentSource2 (sim)0.47 (4 verified)0.182.741.470.070.120.170.072.325.54
Dynawo.Examples.Wind.WECC.WTG4ACurrentSource (sim)4.92 (4 verified)1.232.461.440.060.100.020.212.0810.87
Dynawo.Examples.Wind.WECC.WTG4BCurrentSource (sim)0.46 (4 verified)0.142.261.460.050.110.020.191.894.99
Dynawo.Examples.Wind.WECC.WTG4BCurrentSourceExternalPCS (sim)5.23 (4 verified)1.512.461.430.080.100.020.202.0511.44