Environment - simulationEnvironment: startTime=0 stopTime=6 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0024 Regular simulation: ./ClaRa_dev_ClaRa.Components.Sensors.Check.TestFuelSensors -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa main/Components/BoundaryConditions/BoundaryFuel_pTxi.mo:55:3-56:72:writable] | | | | The following assertion has been violated at time 3.501600 | | | | ((boundaryVLE_phxi.p >= 0.0)) --> "Variable violating min constraint: 0.0 <= boundaryVLE_phxi.p, has value: -320" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.5388e-05s [ 0.1%] pre-initialization LOG_STATS | info | | 0.0282109s [ 56.3%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0s [ 0.0%] solver (excl. callbacks) LOG_STATS | info | | 0.00140173s [ 2.8%] creating output-file LOG_STATS | info | | 0s [ 0.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.0204894s [ 40.9%] simulation LOG_STATS | info | | 0.0501274s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 9 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: euler LOG_STATS | info | | 2509 steps taken LOG_STATS | info | | 2509 calls of functionODE LOG_STATS | info | | 0 evaluations of jacobian LOG_STATS | info | | 0 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0s time of jacobian evaluation