Environment - simulationEnvironment: startTime=0 stopTime=864000 tolerance=1e-06 numberOfIntervals=2500 stepSize=345.6 Regular simulation: ./Buildings_latest_Buildings.DHC.Loads.Combined.Examples.BuildingTimeSeriesWithETSDHWTank -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Resources/Data/DHC/Loads/Examples/SwissOffice_20190916.mos" LOG_ASSERT | error | Model error: Argument of log(u) was -1 should be > 0 LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 1036.800000 | | | | ((bui.ets.proHotWat.valHeaPumEva.actPos.y >= 0.0 and bui.ets.proHotWat.valHeaPumEva.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.valHeaPumEva.actPos.y <= 1.0, has value: -6.25324e-18" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 1036.800000 | | | | ((bui.ets.proHeaWat.valHeaPumEva.actPos.y >= 0.0 and bui.ets.proHeaWat.valHeaPumEva.actPos.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHeaWat.valHeaPumEva.actPos.y <= 1.0, has value: -6.25324e-18" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 7763.766689 | | | | ((bui.ets.proHotWat.pumEva.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.pumEva.etaHyd, has value: -5.38977e-33" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 7763.766689 | | | | ((bui.ets.proHotWat.heaPum.m2_flow >= 0.0 and bui.ets.proHotWat.heaPum.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.heaPum.m2_flow <= 1e5, has value: -2.11442e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7763.766689 | | | | ((bui.ets.pum1HexChi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.pum1HexChi.eff.yMot, has value: -2.97437e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Reals/MultiSum.mo:9:3-11:74:writable] | | | | The following assertion has been violated at time 7823.766727 | | | | ((bui.ets.masFloHeaTot.u[2] >= 0.0 and bui.ets.masFloHeaTot.u[2] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.masFloHeaTot.u[2] <= 1e5, has value: -7.64737e-07" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 7948.800000 | | | | ((bui.ets.proHeaWat.valHeaPumEva.res3.y >= 0.0 and bui.ets.proHeaWat.valHeaPumEva.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHeaWat.valHeaPumEva.res3.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Chillers/BaseClasses/Carnot.mo:127:3-129:56:writable] | | | | The following assertion has been violated at time 21772.800000 | | | | ((bui.ets.proHotWat.heaPum.yPL >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.heaPum.yPL, has value: -6.63586e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 21772.800000 | | | | ((bui.ets.proHotWat.heaPum.m1_flow >= 0.0 and bui.ets.proHotWat.heaPum.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.heaPum.m1_flow <= 1e5, has value: -2.77556e-17" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 21808.380914 | | | | ((bui.ets.proHotWat.heaPumTan.conVal.ram.y >= 0.0 and bui.ets.proHotWat.heaPumTan.conVal.ram.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.heaPumTan.conVal.ram.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 21808.380914 | | | | ((bui.ets.proHotWat.heaPumTan.divVal.res3.y >= 0.0 and bui.ets.proHotWat.heaPumTan.divVal.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.heaPumTan.divVal.res3.y <= 1.0, has value: -2.00232e-10" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 43545.600000 | | | | ((bui.ets.proHotWat.pumCon.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.pumCon.eff.yMot, has value: -1.50802e-28" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 43545.600000 | | | | ((bui.ets.proHotWat.pumCon.motSpe.y >= 0.0 and bui.ets.proHotWat.pumCon.motSpe.y <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.pumCon.motSpe.y <= 1e5, has value: -2.60727e-59" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 44236.800000 | | | | ((bui.ets.proHotWat.pumEva.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.pumEva.eff.yMot, has value: -1.05313e-160" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Actuators/BaseClasses/ActuatorSignal.mo:23:3-30:26:writable] | | | | The following assertion has been violated at time 45619.200000 | | | | ((bui.ets.proHotWat.valHeaPumEva.res3.y >= 0.0 and bui.ets.proHotWat.valHeaPumEva.res3.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHotWat.valHeaPumEva.res3.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 64730.347837 | | | | ((bui.ets.proHotWat.heaPumTan.pumHex.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHotWat.heaPumTan.pumHex.eff.yMot, has value: -9.57797e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Reals/MultiSum.mo:9:3-11:74:writable] | | | | The following assertion has been violated at time 64736.995580 | | | | ((bui.ets.masFloHeaTot.u[1] >= 0.0 and bui.ets.masFloHeaTot.u[1] <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.masFloHeaTot.u[1] <= 1e5, has value: -1.70625e-13" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 64736.995580 | | | | ((bui.ets.proHeaWat.pumEva.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= bui.ets.proHeaWat.pumEva.etaHyd, has value: -3.5654e-29" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 64736.995580 | | | | ((bui.ets.proHeaWat.heaPum.m2_flow >= 0.0 and bui.ets.proHeaWat.heaPum.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= bui.ets.proHeaWat.heaPum.m2_flow <= 1e5, has value: -1.70625e-13" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 4.6227e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.00479442s [ 0.2%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.0996148s [ 4.0%] solver (excl. callbacks) LOG_STATS | info | | 0.0164337s [ 0.7%] creating output-file LOG_STATS | info | | 0.472579s [ 19.1%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 1.88269s [ 76.0%] simulation LOG_STATS | info | | 2.47616s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 141 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 22022 steps taken LOG_STATS | info | | 35951 calls of functionODE LOG_STATS | info | | 5923 evaluations of jacobian LOG_STATS | info | | 1840 error test failures LOG_STATS | info | | 393 convergence test failures LOG_STATS | info | | 1.07496s time of jacobian evaluation