Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_13_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.DecouplingTemperature -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -3.33792e-38" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.pum.pumSpe.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.heaDis.etaHyd, has value: -1.50395e-34" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -1.88862e-31" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -1.87589e-31" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Integers/Sources/TimeTable.mo:14:3-16:72:writable] | | | | The following assertion has been violated at time 21600.000000 | | | | ((mode.y[1] >= 0 and mode.y[1] <= 1)) --> "Variable violating min/max constraint: 0 <= mode.y[1] <= 1, has value: 2" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79384.320000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -6.3008e-73" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 80040.960000 | | | | ((pum.pumDp.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumDp.eff.yMot, has value: -3.86424e-30" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 3.7591e-05s [ 0.0%] pre-initialization | | | | | | 0.00132617s [ 1.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.0143005s [ 11.1%] solver (excl. callbacks) | | | | | | 2.094e-06s [ 0.0%] creating output-file | | | | | | 0.00201072s [ 1.6%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.110616s [ 86.2%] simulation | | | | | | 0.128293s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 13 time events | | | | | solver: dassl | | | | | | 3212 steps taken | | | | | | 4774 calls of functionODE | | | | | | 681 evaluations of jacobian | | | | | | 259 error test failures | | | | | | 45 convergence test failures | | | | | | 0.0388516s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.