Environment - simulationEnvironment: startTime=0 stopTime=9000 tolerance=1e-06 numberOfIntervals=2500 stepSize=3.6 Regular simulation: ./Buildings_13_Buildings.DHC.Plants.Cooling.Examples.StoragePlantDualSource -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pumSup1.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pumSup1.etaHyd, has value: -6.43667e-27" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((stoPla.revCon.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= stoPla.revCon.pum.etaHyd, has value: -5.841e-26" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 1515.600000 | | | | ((stoPla.pumPri.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= stoPla.pumPri.eff.yMot, has value: -4.23658e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 6030.000000 | | | | ((stoPla.revCon.pum.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= stoPla.revCon.pum.eff.yMot, has value: -1.0539e-44" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 4.748e-05s [ 0.0%] pre-initialization | | | | | | 0.00172478s [ 1.6%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00839239s [ 7.6%] solver (excl. callbacks) | | | | | | 5.5e-06s [ 0.0%] creating output-file | | | | | | 0.0304685s [ 27.7%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0694776s [ 63.1%] simulation | | | | | | 0.110116s [100.0%] total | | | | | events | | | | | | 8 state events | | | | | | 10 time events | | | | | solver: dassl | | | | | | 2626 steps taken | | | | | | 4280 calls of functionODE | | | | | | 775 evaluations of jacobian | | | | | | 202 error test failures | | | | | | 60 convergence test failures | | | | | | 0.0264947s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.