Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.ZoneTemperatureInitialization -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2026.09.10 21:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output ZoneTemperatureInitialization.TRad.y has in Modelica the unit K. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.28sec EnergyPlus Completed Successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 3.0688e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 6.1892s [ 98.6%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00182137s [ 0.0%] solver (excl. callbacks) LOG_STATS | info | | 0.00209742s [ 0.0%] creating output-file LOG_STATS | info | | 0.00250806s [ 0.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.0809705s [ 1.3%] simulation LOG_STATS | info | | 6.27662s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 143 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 2405 steps taken LOG_STATS | info | | 2831 calls of functionODE LOG_STATS | info | | 2014 evaluations of jacobian LOG_STATS | info | | 5 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.00418518s time of jacobian evaluation