Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2513 stepSize=240.669 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.TwoIdenticalZones -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2026.09.10 21:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output TwoIdenticalZones.inf1.y has in Modelica the unit 1. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.41sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 604800.000 TwoIdenticalZones.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.2402e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 6.11323s [ 95.2%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.0152488s [ 0.2%] solver (excl. callbacks) LOG_STATS | info | | 0.00620342s [ 0.1%] creating output-file LOG_STATS | info | | 0.0155986s [ 0.2%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.27079s [ 4.2%] simulation LOG_STATS | info | | 6.4211s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 1007 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 13947 steps taken LOG_STATS | info | | 16772 calls of functionODE LOG_STATS | info | | 11529 evaluations of jacobian LOG_STATS | info | | 16 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.0441292s time of jacobian evaluation