Environment - simulationEnvironment: startTime=0 stopTime=432000 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneTwoDifferentOutputVariables -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2026.09.10 21:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneTwoDifferentOutputVariables.equEle.y has in Modelica the unit 1. LOG_STDOUT | info | Output OneZoneTwoDifferentOutputVariables.incBeaSou.y has in Modelica the unit W/m2. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.35sec EnergyPlus Completed Successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.3494e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 6.20532s [ 96.9%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.00751474s [ 0.1%] solver (excl. callbacks) LOG_STATS | info | | 0.00337517s [ 0.1%] creating output-file LOG_STATS | info | | 0.0108033s [ 0.2%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.179755s [ 2.8%] simulation LOG_STATS | info | | 6.4068s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 719 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 10227 steps taken LOG_STATS | info | | 12289 calls of functionODE LOG_STATS | info | | 8520 evaluations of jacobian LOG_STATS | info | | 14 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.0195269s time of jacobian evaluation