Environment - simulationEnvironment: startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.ASHRAE2006Summer -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2026.09.10 21:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/08/2017 Continuing Simulation at 01/08/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/15/2017 Continuing Simulation at 01/15/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/22/2017 Continuing Simulation at 01/22/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/29/2017 Continuing Simulation at 01/29/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/05/2017 Continuing Simulation at 02/05/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/12/2017 Continuing Simulation at 02/12/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/19/2017 Continuing Simulation at 02/19/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/26/2017 Continuing Simulation at 02/26/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/05/2017 Continuing Simulation at 03/05/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/12/2017 Continuing Simulation at 03/12/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/19/2017 Continuing Simulation at 03/19/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/26/2017 Continuing Simulation at 03/26/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/02/2017 Continuing Simulation at 04/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/09/2017 Continuing Simulation at 04/09/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/16/2017 Continuing Simulation at 04/16/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/23/2017 Continuing Simulation at 04/23/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=04/30/2017 Continuing Simulation at 04/30/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/07/2017 Continuing Simulation at 05/07/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/14/2017 Continuing Simulation at 05/14/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/21/2017 Continuing Simulation at 05/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=05/28/2017 Continuing Simulation at 05/28/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/04/2017 Continuing Simulation at 06/04/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/11/2017 Continuing Simulation at 06/11/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/18/2017 Continuing Simulation at 06/18/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=06/25/2017 Continuing Simulation at 06/25/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=07/02/2017 Continuing Simulation at 07/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=07/09/2017 Continuing Simulation at 07/09/2017 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16849036.800000 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -3.89241e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 16849036.800000 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -1.57895e-20" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16850592.000000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -7.00307e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16850592.000000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -3.59566e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16850592.000000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -5.3088e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16850592.000000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -3.59566e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16850592.000000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -5.3088e-11" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -3.4187e-45" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -3.1662e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -2.1912e-26" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -1.46909e-46" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 16916601.600000 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -1.07081e-30" Updating Shadowing Calculations, Start Date=07/16/2017 Continuing Simulation at 07/16/2017 for SPAWN-RUNPERIOD LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:115:3-116:81:writable] | | | | The following assertion has been violated at time 17089401.600000 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -2.81467e-12" LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 01min 42.20sec EnergyPlus Completed Successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 3.676e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 9.70884s [ 9.0%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 3.27264s [ 3.0%] solver (excl. callbacks) LOG_STATS | info | | 0.0407061s [ 0.0%] creating output-file LOG_STATS | info | | 5.08802s [ 4.7%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 90.1369s [ 83.3%] simulation LOG_STATS | info | | 108.247s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 765 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 108251 steps taken LOG_STATS | info | | 212353 calls of functionODE LOG_STATS | info | | 113698 evaluations of jacobian LOG_STATS | info | | 1699 error test failures LOG_STATS | info | | 33675 convergence test failures LOG_STATS | info | | 82.1362s time of jacobian evaluation