Environment - simulationEnvironment: startTime=7.776e+06 stopTime=9.504e+06 tolerance=1e-06 numberOfIntervals=6325 stepSize=273.202 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SingleFamilyHouse.RadiantHeatingCooling_TRoom -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2026.09.10 21:13 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/21/2017 Continuing Simulation at 01/21/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/10/2017 Continuing Simulation at 02/10/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/02/2017 Continuing Simulation at 03/02/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/22/2017 Continuing Simulation at 03/22/2017 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 7776000.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 7797036.521739 | | | | ((slaFlo.port_b.m_flow >= -1e5 and slaFlo.port_b.m_flow <= 0.0)) --> "Variable violating min/max constraint: -1e5 <= slaFlo.port_b.m_flow <= 0.0, has value: 4.27985e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/HeatExchangers/RadiantSlabs/ParallelCircuitsSlab.mo:58:3-59:107:writable] | | | | The following assertion has been violated at time 7797036.521739 | | | | ((slaFlo.m_flow >= 0.0 and slaFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= slaFlo.m_flow <= 1e5, has value: -4.27985e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 7797036.521739 | | | | ((slaFlo.sla.m_flow >= 0.0 and slaFlo.sla.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= slaFlo.sla.m_flow <= 1e5, has value: -1.42662e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 7797036.521739 | | | | ((pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.etaHyd, has value: -1.66951e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 7797036.521739 | | | | ((pum.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.heaDis.etaHyd, has value: -1.78081e-23" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7797582.924901 | | | | ((pum.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.eff.yMot, has value: -4.40139e-35" Updating Shadowing Calculations, Start Date=04/11/2017 Continuing Simulation at 04/11/2017 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 2.56sec EnergyPlus Completed Successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.0869e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 7.13623s [ 82.7%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.198596s [ 2.3%] solver (excl. callbacks) LOG_STATS | info | | 0.0220357s [ 0.3%] creating output-file LOG_STATS | info | | 0.0618095s [ 0.7%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 1.20848s [ 14.0%] simulation LOG_STATS | info | | 8.62717s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 1504 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 33893 steps taken LOG_STATS | info | | 46051 calls of functionODE LOG_STATS | info | | 17554 evaluations of jacobian LOG_STATS | info | | 594 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.396762s time of jacobian evaluation