Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-08 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPum: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPum: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPumSou: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPumSou: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/HeatPumps/BaseClasses/PartialWaterToWater.mo:84:3-89:58:writable] | | | | The following assertion has been violated at time 26905.567010 | | | | ((heaPum.P >= 0.0)) --> "Variable violating min constraint: 0.0 <= heaPum.P, has value: -6.01853e-36" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 5.6697e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.0232342s [ 1.0%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.0280867s [ 1.2%] solver (excl. callbacks) LOG_STATS | info | | 0.00486799s [ 0.2%] creating output-file LOG_STATS | info | | 0.771433s [ 33.1%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 1.50438s [ 64.5%] simulation LOG_STATS | info | | 2.33206s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 150 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 27279 steps taken LOG_STATS | info | | 31250 calls of functionODE LOG_STATS | info | | 3521 evaluations of jacobian LOG_STATS | info | | 294 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.298075s time of jacobian evaluation