Environment - simulationEnvironment: startTime=0 stopTime=10000 tolerance=1e-06 numberOfIntervals=2500 stepSize=4 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.Examples.ResistanceVolumeFlowReversal -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ResistanceVolumeFlowReversal.pump: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ResistanceVolumeFlowReversal.pump: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Interfaces/PartialTwoPortInterface.mo:19:3-20:81:writable] | | | | The following assertion has been violated at time 500.000000 | | | | ((hea.m_flow >= 0.0 and hea.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hea.m_flow <= 1e5, has value: -9.83908e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Interfaces/PartialTwoPortInterface.mo:19:3-20:81:writable] | | | | The following assertion has been violated at time 500.000000 | | | | ((res[10].m_flow >= 0.0 and res[10].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= res[10].m_flow <= 1e5, has value: -2.29757e-26" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Interfaces/PrescribedOutlet.mo:103:3-104:95:writable] | | | | The following assertion has been violated at time 604.000000 | | | | ((hea.outCon.T >= 0.0)) --> "Variable violating min constraint: 0.0 <= hea.outCon.T, has value: -5.78078e-06" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 2.5328e-05s [ 0.1%] pre-initialization LOG_STATS | info | | 0.000457541s [ 1.6%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.000823576s [ 2.9%] solver (excl. callbacks) LOG_STATS | info | | 0.00285026s [ 10.1%] creating output-file LOG_STATS | info | | 0.00101935s [ 3.6%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 0.023085s [ 81.7%] simulation LOG_STATS | info | | 0.0282611s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 19 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 939 steps taken LOG_STATS | info | | 1330 calls of functionODE LOG_STATS | info | | 309 evaluations of jacobian LOG_STATS | info | | 39 error test failures LOG_STATS | info | | 0 convergence test failures LOG_STATS | info | | 0.00342799s time of jacobian evaluation