Environment - simulationEnvironment: startTime=0 stopTime=29600 tolerance=1e-06 numberOfIntervals=29600 stepSize=1 Regular simulation: ./AixLib_AixLib.Fluid.MassExchangers.MembraneBasedEnthalpyExchangers.Validation.StaticValidation -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_STDOUT | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationEta.txt" LOG_STDOUT | info | ... loading "Boundary" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationOda.txt" LOG_STDOUT | info | ... loading "Result" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Resources/Fluid/MembraneBasedEnthalpyExchanger/StaticValidationResult.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in StaticValidation.fan: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in StaticValidation.fan1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Sensors/RelativeHumidityTwoPort.mo:5:3-11:26:writable] | | | | The following assertion has been violated at time 4811.000000 | | | | ((enthalpyExchanger.airDuct1.senRelHum.phi >= 0.01 and enthalpyExchanger.airDuct1.senRelHum.phi <= 0.99)) --> "Variable violating min/max constraint: 0.01 <= enthalpyExchanger.airDuct1.senRelHum.phi <= 0.99, has value: 0.996883" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 3.8413e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.00334365s [ 0.1%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.162374s [ 2.4%] solver (excl. callbacks) LOG_STATS | info | | 0.231906s [ 3.5%] creating output-file LOG_STATS | info | | 0.0113031s [ 0.2%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 6.27612s [ 93.9%] simulation LOG_STATS | info | | 6.68508s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 72 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 5604 steps taken LOG_STATS | info | | 8229 calls of functionODE LOG_STATS | info | | 1297 evaluations of jacobian LOG_STATS | info | | 205 error test failures LOG_STATS | info | | 93 convergence test failures LOG_STATS | info | | 2.20569s time of jacobian evaluation