Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=173 stepSize=499.422 Regular simulation: ./AixLib_AixLib.Fluid.Examples.GeothermalHeatPump.GeothermalHeatPump -abortSlowSimulation -alarm=240 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpColdConsumer.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpColdConsumer: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpHeatConsumer.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpHeatConsumer: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpCondenser.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpCondenser: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpEvaporator.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpEvaporator: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpGeothermalSource.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GeothermalHeatPump.pumpGeothermalSource: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/FixedResistances/BaseClasses/PlugFlowHeatLoss.mo:30:3-31:48:writable] | | | | The following assertion has been violated at time 15482.080925 | | | | ((heatStorage.heatingCoil1.pipe[1].heaLos_a.T_a_inflow >= 0.0)) --> "Variable violating min constraint: 0.0 <= heatStorage.heatingCoil1.pipe[1].heaLos_a.T_a_inflow, has value: -157.708" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 3.0.1/Fluid/FixedResistances/BaseClasses/PlugFlowHeatLoss.mo:32:3-33:49:writable] | | | | The following assertion has been violated at time 15482.080925 | | | | ((heatStorage.heatingCoil1.pipe[1].heaLos_a.T_b_outflow >= 0.0)) --> "Variable violating min constraint: 0.0 <= heatStorage.heatingCoil1.pipe[1].heaLos_a.T_b_outflow, has value: -157.708" LOG_SUCCESS | info | The simulation finished successfully. LOG_STATS | info | ### STATISTICS ### LOG_STATS | info | timer LOG_STATS | info | | 0s reading init.xml LOG_STATS | info | | 0s reading info.xml LOG_STATS | info | | 3.8222e-05s [ 0.0%] pre-initialization LOG_STATS | info | | 0.00221787s [ 0.0%] initialization LOG_STATS | info | | 0s [ 0.0%] steps LOG_STATS | info | | 0.557354s [ 6.3%] solver (excl. callbacks) LOG_STATS | info | | 0.00581574s [ 0.1%] creating output-file LOG_STATS | info | | 1.85588s [ 21.0%] event-handling LOG_STATS | info | | 0s [ 0.0%] overhead LOG_STATS | info | | 6.43198s [ 72.7%] simulation LOG_STATS | info | | 8.85329s [100.0%] total LOG_STATS | info | events LOG_STATS | info | | 332 state events LOG_STATS | info | | 0 time events LOG_STATS | info | solver: dassl LOG_STATS | info | | 30990 steps taken LOG_STATS | info | | 49934 calls of functionODE LOG_STATS | info | | 9301 evaluations of jacobian LOG_STATS | info | | 3025 error test failures LOG_STATS | info | | 444 convergence test failures LOG_STATS | info | | 4.44026s time of jacobian evaluation