Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.001 Regular simulation: ./ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.Volumes -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialVolume.mo:115:3-115:141:writable] | | | | The following assertion has been violated at time 0.001000 | | | | ((flowResistance10.inlet.m_flow > volume1.m_flow_assert)) --> "In "Volumes.volume1": Positive mass flow rate at Volume outlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialVolume.mo:114:3-114:138:writable] | | | | The following assertion has been violated at time 0.001000 | | | | ((flowResistance11.inlet.m_flow > volume1.m_flow_assert)) --> "In "Volumes.volume1": Negative mass flow rate at Volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialVolumeN.mo:109:3-109:141:writable] | | | | The following assertion has been violated at time 0.001000 | | | | ((flowResistance14.inlet.m_flow > volumeMix3.m_flow_assert)) --> "In "Volumes.volumeMix3": Positive mass flow rate at volume outlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialVolumeN.mo:107:4-107:142:writable] | | | | The following assertion has been violated at time 0.003000 | | | | ((flowResistance13.inlet.m_flow > volumeMix3.m_flow_assert)) --> "In "Volumes.volumeMix3": Negative mass flow rate at volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialVolumeN.mo:107:4-107:142:writable] | | | | The following assertion has been violated at time 0.020000 | | | | ((flowResistance12.inlet.m_flow > volumeMix3.m_flow_assert)) --> "In "Volumes.volumeMix3": Negative mass flow rate at volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialVolume.mo:114:3-114:138:writable] | | | | The following assertion has been violated at time 0.053000 | | | | ((flowResistance7.inlet.m_flow > heatportVolume1.m_flow_assert)) --> "In "Volumes.heatportVolume1": Negative mass flow rate at Volume inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialVolume.mo:115:3-115:141:writable] | | | | The following assertion has been violated at time 0.162000 | | | | ((flowResistance9.inlet.m_flow > heatportVolume2.m_flow_assert)) --> "In "Volumes.heatportVolume2": Positive mass flow rate at Volume outlet" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.017275s reading init.xml | | | | | | 0.00158684s reading info.xml | | | | | | 0.000542741s [ 0.4%] pre-initialization | | | | | | 0.000873001s [ 0.6%] initialization | | | | | | 0.000134232s [ 0.1%] steps | | | | | | 0.00546202s [ 3.7%] solver (excl. callbacks) | | | | | | 0.000521212s [ 0.4%] creating output-file | | | | | | 9.063e-06s [ 0.0%] event-handling | | | | | | 0.00166018s [ 1.1%] overhead | | | | | | 0.136478s [ 93.7%] simulation | | | | | | 0.14568s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2149 steps taken | | | | | | 3057 calls of functionODE | | | | | | 91 evaluations of jacobian | | | | | | 39 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0146367s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.