Environment - simulationEnvironment: startTime=0 stopTime=10 tolerance=1e-06 numberOfIntervals=1000 stepSize=0.01 Regular simulation: ./ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.Condenser -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0476394s reading init.xml | | | | | | 0.00440005s reading info.xml | | | | | | 0.00918642s [ 0.5%] pre-initialization | | | | | | 0.00367304s [ 0.2%] initialization | | | | | | 0.000629794s [ 0.0%] steps | | | | | | 0.00330316s [ 0.2%] solver (excl. callbacks) | | | | | | 0.00352252s [ 0.2%] creating output-file | | | | | | 3.0769e-05s [ 0.0%] event-handling | | | | | | 0.00441415s [ 0.2%] overhead | | | | | | 1.94493s [ 98.7%] simulation | | | | | | 1.96969s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 299 steps taken | | | | | | 413 calls of functionODE | | | | | | 58 evaluations of jacobian | | | | | | 14 error test failures | | | | | | 0 convergence test failures | | | | | | 1.28838s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.