Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001531/0.001531, allocations: 77.97 kB / 21.46 MB, free: 3.043 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001088/0.001088, allocations: 165.5 kB / 24.86 MB, free: 8.66 MB / 18.57 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 0.7678/0.7678, allocations: 158.6 MB / 186.8 MB, free: 2.793 MB / 170.7 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo): time 0.3917/0.3917, allocations: 76.92 MB / 316 MB, free: 10.63 MB / 298.7 MB " [Timeout remaining time 180] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2,tolerance=0.001,outputFormat="empty",numberOfIntervals=5250,variableFilter="",fileNamePrefix="Dynawo_Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2") translateModel(Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2,tolerance=0.001,outputFormat="empty",numberOfIntervals=5250,variableFilter="",fileNamePrefix="Dynawo_Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 1.733e-06/1.733e-06, allocations: 0 / 411.1 MB, free: 13.34 MB / 394.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 2.082e-05/2.255e-05, allocations: 6.312 kB / 411.1 MB, free: 13.33 MB / 394.7 MB Notification: Performance of NFInst.instantiate(Dynawo.Electrical.Controls.Machines.Governors.Standard.Generic.GovCt2): time 0.004727/0.00475, allocations: 4.306 MB / 415.4 MB, free: 8.992 MB / 394.7 MB Notification: Performance of NFInst.instExpressions: time 0.002242/0.006992, allocations: 1.607 MB / 417 MB, free: 7.375 MB / 394.7 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.0003053/0.007297, allocations: 27.81 kB / 417 MB, free: 7.348 MB / 394.7 MB Notification: Performance of NFTyping.typeComponents: time 0.0005794/0.007876, allocations: 293.9 kB / 417.3 MB, free: 7.059 MB / 394.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.0005575/0.008434, allocations: 317.9 kB / 417.6 MB, free: 6.746 MB / 394.7 MB Notification: Performance of NFTyping.typeClassSections: time 0.0006936/0.009127, allocations: 0.5223 MB / 418.2 MB, free: 6.223 MB / 394.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:18:3-19:42:writable] Error: Parameter aSetPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:20:3-21:39:writable] Error: Parameter DeltaOmegaDbPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:22:3-23:39:writable] Error: Parameter DeltaOmegaMaxPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:24:3-25:39:writable] Error: Parameter DeltaOmegaMinPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:26:3-27:42:writable] Error: Parameter DeltaT has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:28:3-29:36:writable] Error: Parameter Dm has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:30:3-31:53:writable] Error: Parameter fLim10Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:32:3-33:53:writable] Error: Parameter fLim1Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:34:3-35:53:writable] Error: Parameter fLim2Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:36:3-37:53:writable] Error: Parameter fLim3Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:38:3-39:53:writable] Error: Parameter fLim4Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:40:3-41:53:writable] Error: Parameter fLim5Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:42:3-43:53:writable] Error: Parameter fLim6Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:44:3-45:53:writable] Error: Parameter fLim7Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:46:3-47:53:writable] Error: Parameter fLim8Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:48:3-49:53:writable] Error: Parameter fLim9Hz has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:50:3-51:42:writable] Error: Parameter KA has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:52:3-53:39:writable] Error: Parameter KDGov has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:54:3-55:39:writable] Error: Parameter KIGov has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:56:3-57:43:writable] Error: Parameter KILoad has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:58:3-59:49:writable] Error: Parameter KIMw has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:60:3-61:39:writable] Error: Parameter KPGov has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:62:3-63:43:writable] Error: Parameter KPLoad has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:64:3-65:36:writable] Error: Parameter KTurb has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:66:3-67:29:writable] Error: Parameter PBaseMw has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:68:3-69:29:writable] Error: Parameter PGenBaseMw has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:70:3-71:43:writable] Error: Parameter PLdRefPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:72:3-73:53:writable] Error: Parameter PLim10Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:74:3-75:53:writable] Error: Parameter PLim1Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:76:3-77:53:writable] Error: Parameter PLim2Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:78:3-79:53:writable] Error: Parameter PLim3Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:80:3-81:53:writable] Error: Parameter PLim4Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:82:3-83:53:writable] Error: Parameter PLim5Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:84:3-85:53:writable] Error: Parameter PLim6Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:86:3-87:53:writable] Error: Parameter PLim7Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:88:3-89:53:writable] Error: Parameter PLim8Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:90:3-91:53:writable] Error: Parameter PLim9Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:92:3-93:53:writable] Error: Parameter PRatePu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:94:3-95:36:writable] Error: Parameter RClosePu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:96:3-97:43:writable] Error: Parameter RDownPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:98:3-99:36:writable] Error: Parameter ROpenPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:100:3-101:39:writable] Error: Parameter RDroop has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:102:3-103:39:writable] Error: Parameter RSelectInt has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:104:3-105:43:writable] Error: Parameter RUpPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:106:3-107:36:writable] Error: Parameter tActuator has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:108:3-109:42:writable] Error: Parameter tA has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:110:3-111:36:writable] Error: Parameter tB has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:112:3-113:36:writable] Error: Parameter tC has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:114:3-115:39:writable] Error: Parameter tDGov has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:116:3-116:105:writable] Error: Parameter tDRatelim has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:117:3-118:36:writable] Error: Parameter tEngine has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:119:3-120:43:writable] Error: Parameter tFLoad has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:121:3-122:39:writable] Error: Parameter tLastValue has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:123:3-124:39:writable] Error: Parameter tPElec has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:125:3-126:43:writable] Error: Parameter tSA has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:127:3-128:43:writable] Error: Parameter tSB has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:129:3-130:36:writable] Error: Parameter ValveMaxPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:131:3-132:36:writable] Error: Parameter ValveMinPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:133:3-134:36:writable] Error: Parameter WFnlPu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:135:3-136:36:writable] Error: Parameter WFSpdBool has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:287:3-287:203:writable] Error: Parameter PGen0Pu has neither value nor start value, and is fixed during initialization (fixed=true). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0/Electrical/Controls/Machines/Governors/Standard/Generic/GovCt2.mo:288:3-288:95:writable] Error: Parameter Pm0Pu has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of NFFlatten.flatten: time 0.0008418/0.009969, allocations: 1.061 MB / 419.2 MB, free: 5.156 MB / 394.7 MB Notification: Performance of NFFlatten.resolveConnections: time 0.000342/0.01031, allocations: 267.5 kB / 419.5 MB, free: 4.875 MB / 394.7 MB Notification: Performance of NFEvalConstants.evaluate: time 0.0003254/0.01064, allocations: 422.5 kB / 419.9 MB, free: 4.461 MB / 394.7 MB Notification: Performance of NFSimplifyModel.simplify: time 0.0003807/0.01102, allocations: 430.5 kB / 420.3 MB, free: 4.039 MB / 394.7 MB Notification: Performance of NFPackage.collectConstants: time 9.128e-05/0.01111, allocations: 72 kB / 420.4 MB, free: 3.969 MB / 394.7 MB Notification: Performance of NFFlatten.collectFunctions: time 0.0001301/0.01124, allocations: 103.9 kB / 420.5 MB, free: 3.867 MB / 394.7 MB Notification: Performance of NFScalarize.scalarize: time 0.0001941/0.01143, allocations: 298.7 kB / 420.8 MB, free: 3.574 MB / 394.7 MB Notification: Performance of NFVerifyModel.verify: time 0.0002144/0.01165, allocations: 310.8 kB / 421.1 MB, free: 3.27 MB / 394.7 MB Notification: Performance of NFConvertDAE.convert: time 0.0006356/0.01228, allocations: 0.7776 MB / 421.9 MB, free: 2.488 MB / 394.7 MB Notification: Performance of FrontEnd - DAE generated: time 2.886e-06/0.01229, allocations: 3.938 kB / 421.9 MB, free: 2.484 MB / 394.7 MB Notification: Performance of FrontEnd: time 7.92e-07/0.01229, allocations: 0 / 421.9 MB, free: 2.484 MB / 394.7 MB Notification: Performance of Transformations before backend: time 7.334e-06/0.01229, allocations: 4 kB / 421.9 MB, free: 2.48 MB / 394.7 MB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 163 * Number of variables: 163 Notification: Performance of Generate backend data structure: time 0.001546/0.01384, allocations: 1.565 MB / 423.4 MB, free: 0.8711 MB / 394.7 MB Notification: Performance of prepare preOptimizeDAE: time 3.486e-05/0.01387, allocations: 16.03 kB / 423.4 MB, free: 0.8555 MB / 394.7 MB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0001799/0.01405, allocations: 200 kB / 423.6 MB, free: 0.6602 MB / 394.7 MB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0007139/0.01477, allocations: 0.6496 MB / 424.3 MB, free: 15.96 MB / 410.7 MB Notification: Performance of preOpt simplifyIfEquations (simulation): time 9.542e-05/0.01486, allocations: 113.3 kB / 424.4 MB, free: 15.84 MB / 410.7 MB Notification: Performance of preOpt expandDerOperator (simulation): time 7.459e-05/0.01494, allocations: 64.38 kB / 424.5 MB, free: 15.78 MB / 410.7 MB Notification: Performance of preOpt clockPartitioning (simulation): time 0.0006608/0.0156, allocations: 0.7263 MB / 425.2 MB, free: 14.96 MB / 410.7 MB Notification: Performance of preOpt findStateOrder (simulation): time 1.575e-05/0.01562, allocations: 4 kB / 425.2 MB, free: 14.96 MB / 410.7 MB Notification: Performance of preOpt replaceEdgeChange (simulation): time 3.872e-05/0.01565, allocations: 32 kB / 425.2 MB, free: 14.93 MB / 410.7 MB Notification: Performance of preOpt inlineArrayEqn (simulation): time 1.296e-05/0.01567, allocations: 16 kB / 425.2 MB, free: 14.91 MB / 410.7 MB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.0002814/0.01595, allocations: 210.1 kB / 425.4 MB, free: 14.71 MB / 410.7 MB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.001884/0.01783, allocations: 2.24 MB / 427.7 MB, free: 12.41 MB / 410.7 MB Notification: Performance of preOpt comSubExp (simulation): time 0.0005948/0.01843, allocations: 377.2 kB / 428.1 MB, free: 12.02 MB / 410.7 MB Notification: Performance of preOpt resolveLoops (simulation): time 0.0001315/0.01856, allocations: 109.1 kB / 428.2 MB, free: 11.91 MB / 410.7 MB Notification: Performance of preOpt evalFunc (simulation): time 3.806e-05/0.0186, allocations: 20.48 kB / 428.2 MB, free: 11.89 MB / 410.7 MB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 2.526e-05/0.01862, allocations: 45.83 kB / 428.2 MB, free: 11.84 MB / 410.7 MB Notification: Performance of pre-optimization done (n=60): time 1.983e-06/0.01862, allocations: 0 / 428.2 MB, free: 11.84 MB / 410.7 MB Notification: Performance of matching and sorting (n=60): time 0.0005759/0.0192, allocations: 468.8 kB / 428.7 MB, free: 11.38 MB / 410.7 MB Notification: Performance of inlineWhenForInitialization (initialization): time 4.968e-05/0.01925, allocations: 137 kB / 428.8 MB, free: 11.21 MB / 410.7 MB Error: No system for the symbolic initialization was generated " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 1.7926693917252123]