Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_12_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariableReturn -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_STDOUT | info | *** Warning: In InjectionTwoWayVariableReturn.con: Return temperature control is likely not compatible with a variable flow consumer circuit. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 36391.680000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -5.66237e-34" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -2.3625e-30" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.eff.yMot, has value: -8.84621e-79" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.etaHyd, has value: -6.2075e-60" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.2-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79280.640000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -1.78819e-57" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0877747s reading init.xml | | | | | | 0.00844507s reading info.xml | | | | | | 0.00220862s [ 1.4%] pre-initialization | | | | | | 0.00415811s [ 2.5%] initialization | | | | | | 0.000129984s [ 0.1%] steps | | | | | | 0.0116293s [ 7.1%] solver (excl. callbacks) | | | | | | 0.00269684s [ 1.7%] creating output-file | | | | | | 0.00151848s [ 0.9%] event-handling | | | | | | 0.00646356s [ 4.0%] overhead | | | | | | 0.134612s [ 82.4%] simulation | | | | | | 0.163417s [100.0%] total | | | | | events | | | | | | 8 state events | | | | | | 4 time events | | | | | solver: dassl | | | | | | 2587 steps taken | | | | | | 4147 calls of functionODE | | | | | | 548 evaluations of jacobian | | | | | | 186 error test failures | | | | | | 28 convergence test failures | | | | | | 0.0476713s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.