startTime=1.5552e+07 stopTime=1.5984e+07 tolerance=1e-06 numberOfIntervals=120 stepSize=3600 wasm-jit simulation: simulate(Buildings.Utilities.Plotters.Examples.SingleZoneVAV,startTime=1.5552e+07,stopTime=1.5984e+07,tolerance=1e-06,numberOfIntervals=120,outputFormat="mat",variableFilter="time|hvac.PFan",fileNamePrefix="Buildings_11_Buildings.Utilities.Plotters.Examples.SingleZoneVAV",simflags="-abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 15668280.437048 | | | | ((hvac.cooCoi.m1_flow >= 0.0 and hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.m1_flow <= 1e5, has value: -5.04871e-29" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.2-maint.11.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 15669200.147152 | | | | ((hvac.ideVal.preMasFlo.m_flow >= 0.0 and hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -2.52435e-29" LOG_STDOUT | info | Wrote plot file "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/plots.html". LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 8.9368e-05s [ 0.0%] pre-initialization | | | | | | 0.0270101s [ 2.5%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.18311s [ 16.8%] solver (excl. callbacks) | | | | | | 0.00185857s [ 0.2%] creating output-file | | | | | | 0.136695s [ 12.5%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.742296s [ 68.0%] simulation | | | | | | 1.09106s [100.0%] total | | | | | events | | | | | | 65 state events | | | | | | 481 time events | | | | | solver: | | | | | | 13368 steps taken | | | | | | 18928 calls of functionODE | | | | | | 6184 evaluations of jacobian | | | | | | 724 error test failures | | | | | | 2 convergence test failures | | | | | | 0.562515s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.