startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=8760 stepSize=3600 wasm artifact (me: FMI 3.0 Model Exchange, integrated by omc with DASKR (IDA over the fmi-ls-dae residuals for a --daeMode model)): simulate(Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case600FF,startTime=0,stopTime=3.1536e+07,tolerance=1e-06,numberOfIntervals=8760,outputFormat="mat",variableFilter="time|TRooHou.y",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case600FF",simflags=" -alarm=240 -emit_protected -lv LOG_STATS -startTime=0 -stopTime=3.1536e+07 -tolerance=1e-06 -stepSize=3600 -r=Buildings_latest_Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case600FF_me_res.mat -s fmi3:me:daskr",resimulateExecutable="Buildings_latest_Buildings_ThermalZones_ISO13790_Validation_BESTEST_Cases6xx_Case600FF.fmu") LOG_STDOUT | info | wasm artifact loaded in 0.3 ms (model kernel linked against the cached adapter, 1.1 MB) LOG_STDOUT | info | ModelExchange instantiated in 389.0 ms LOG_STDOUT | info | ModelExchange run: 18 steps, 495288 evaluations, 34593 Jacobians, 2 state events, 0 time events, 8765 samples in 4131.4 ms LOG_SUCCESS | info | The simulation finished successfully.